You can import external fields from an output database (.sim)
file, also referred to as a SIM database (see The Output Database), or from another output database for which a Reader
process is available. Once imported, the external field can be used to define
distributions, initial conditions, and history-dependent fields (such as loads,
boundary conditions, and predefined fields). External fields can also be used for
node-based submodeling as discussed in About Submodeling.
The external field can be evaluated at nodes, integration points, or element centers.
Conservative mapping is performed automatically if the fields are evaluated at
different locations or if the meshes are different. Importing an external field is
supported for most two-dimensional and three-dimensional continuum elements. When
used to define distributions and initial conditions, external fields are also
supported for three-dimensional conventional shell elements made of a single
material. All field quantities are exchanged in the global Cartesian coordinate
system.
External fields can be read from various supported output databases. A reader
process, an executable designed to read a particular database format, is started by
the Abaqus driver to read and transfer the field data. By default, the SIM database
(.sim file) reader is used.
You can import external fields from a SIM database (.sim) file.
You specify the file name (including the file extension) from which to import
external fields.
You can import history-dependent fields from a supported non-SIM database. You must
specify the reader executable name and database file name. Consult the respective
solver manual to install and determine the reader executable name.
Input File Usage
Use the following option to specify a SIM database:
Use the following option to specify a non-SIM database file name and reader
executable name:
EXTERNAL FIELD, READER=reader executable name, FILE=file name
Importing an External Field to Define Distributions
You can import external fields to define distributions (see Defining Distributions by Importing Field Data from an Output Database File). A common case is an injection molding manufacturing process where a molten
fibrous material is injected into a mold. You can use injection molding software to
model the manufacturing process and then import the section and material properties
(such as local element orientation and fiber dispersion) into a subsequent
stress-displacement simulation.
Input File Usage
Use the following options to import an external field to define a
distribution:
Importing an External Field to Adjust Nodal Coordinates
You can import an external field to adjust nodal coordinates.
One common case is to introduce a geometric imperfection into a model for a
postbuckling analysis. In this case, the previous analysis must contain the mode
shapes from an eigenfrequency extraction analysis or nodal displacements from a
static or dynamic analysis. Mapping is performed if the postbuckling analysis uses a
dissimilar mesh. The imperfection is introduced by adjusting the nodal coordinates
using the imported modal shapes or nodal displacements.
Another common case is to adjust nodal coordinates using the deformed configuration
from a previous analysis. In this case, the previous analysis must write the nodal
displacements to a SIM database.
Input File Usage
Use the following options to import mode shapes to introduce a geometric
imperfection:
ADJUST, NODE SET=nset, DISTRIBUTION=distribution nameDISTRIBUTION, NAME=distribution name, TABLE=distribution table name
, field dataEXTERNAL FIELD, FILE=file name, MODE=mode numberDISTRIBUTION TABLE, NAME=distribution table name
Use the following options to import nodal displacements to adjust nodal
coordinates:
ADJUST, NODE SET=nset, DISTRIBUTION=distribution nameDISTRIBUTION, NAME=distribution name, TABLE=distribution table name
, field dataEXTERNAL FIELD, FILE=file nameDISTRIBUTION TABLE, NAME=distribution table name
Importing an External Field to Define Initial Conditions
You can import an external field to define initial conditions (see Initial Conditions). A common case
is a geomechanics analysis where you import an initial pore pressure field. You can
compute a pore pressure field using a reservoir code and then import the field into
a subsequent geostatic stress state procedure (see Geostatic Stress State). This procedure is used to compute the
equilibrium state before performing a geotechnical analysis using the coupled pore
fluid diffusion and stress analysis procedure in Abaqus (see Coupled Pore Fluid Diffusion and Stress Analysis). In this case, the reservoir
code must write the pore pressure to a SIM database.
Input File Usage
Use the following options to import an external field to define initial
conditions:
Importing an External Field to Define History-Dependent Fields
You can import external fields to define loads, boundary conditions, and predefined
fields. A common case is a sequential thermal-stress analysis, where you first
perform a heat transfer analysis (see Uncoupled Heat Transfer Analysis) to
compute a temperature field and then import the temperatures into a subsequent
stress-displacement analysis (see Static Stress Analysis).
You can import external fields for the following time-based analysis procedures:
External fields can be imported only in one analysis step per analysis. The analysis
step must be a general analysis (nonperturbation) step. For any subsequent analysis
steps, the applied external fields remain constant based on the last imported
values.
Input File Usage
Use the following options to import an external field to define a load,
boundary condition, or predefined field:
If the previous analysis is an Abaqus analysis, you request the source fields to write to the output database
(.sim) file. When importing external fields over a time range,
you must request output at a frequency to achieve sufficient solution accuracy (see
Controlling the Frequency of Output to the Output Database).
Identifying the Target and Source Fields
When importing an external field, you define the target and source fields. The target
field is the field defined in the current analysis. The source field is the field
computed in a previous analysis. A field is a physical quantity that spans a region.
The field is a node-based field if evaluated at nodes or an element-based field if
evaluated at element centroids, integration points, or surface facets. You define a
region by specifying a node set, an element set, or a surface regardless of where
the field is evaluated.
When a node-based field is imported and an element set from the previous model is
specified, the field is extracted from nodes of the elements in the specified
element set. Similarly, when a node-based field is imported and a surface from the
previous model is specified, the field is extracted from the nodes belonging to the
surface facets of the specified surface. When an element-based field is imported and
a node set from the previous model is specified, the element field is extracted from
elements containing the nodes in the node set. Elements connected to nodes that are
not in the node set are not included.
When importing an external field, you specify the region name space, the region name,
and the physics quantity for the target field and the source field. The region name
space specifies whether the region is a node set, an element set, or a surface. The
region name is the name of a node set, element set, or surface.
When specifying the target field and source field parameters, you should consider the
following conditions:
The source field region name is optional. If it is not specified, the entire
model is used. However, you are encouraged to provide the source field region
name to reduce the computational cost associated with mapping and data transfer.
Abaqus has complex naming conventions, especially for assembly definitions. The
source file name must correspond to the name written to the SIM results file
when reading from a previous Abaqus analysis.
When defining initial conditions, the target field region name space and physics
quantities are defined by the initial condition definition and, consequently,
are not used.
When defining distributions, the target field region name space, region name,
and physics quantities are defined by the distribution definition and,
consequently, are not used.
When used for node-based submodeling, the target region is a node set.
The physics quantities for the target field and the source field are defined using
identifiers. The physics quantity identifiers for the target field depend on the
analysis procedure and are the same identifiers used for co-simulation for imported
fields. Table 1 lists the supported identifiers, and detailed information is
provided in Identifying the Fields Exchanged across a Co-Simulation Interface). Most field-type quantities can be extracted from
the output database file. If the source analysis is an Abaqus analysis, the identifiers are defined in Abaqus/Standard
output variable identifiers and Abaqus/Explicit Output Variable Identifiers. Certain output variables are inconsistent between Abaqus solvers. For example, Abaqus/Standard uses the variable NT and Abaqus/Explicit uses the variable NT11 to output nodal temperatures. You should visualize the
results database to obtain the appropriate field name.
Table 1. Supported target field identifiers.
Analysis
Physics Quantity ID
Description
Analysis procedures supporting mechanical degrees of
freedom
U
Displacement
V
Velocity
CF
Concentrated force at a node
CM
Concentrated moment at a node
P1, 2
Surface pressure
TRVEC1, 2
Surface traction vector
Analysis procedures supporting thermal degrees of
freedom
NT
Nodal temperature
CFL
Concentrated heat flux at a node
HFL1, 2
Surface heat flux
Analysis procedures supporting pore fluid pressure
degree of freedom
POR1
Pore pressure
CFF
Concentrated fluid flow at a node
Analysis procedures supporting mass concentration
CFL
Concentrated mass flux at a node
SINV
Equivalent pressure stress
NNC
Normalized concentration
Analysis procedures supporting electric
potential
EPOT
Electric potential
ECD
Electric current density
All procedures
FVn
Predefined field
ESDVn1
Element solution-dependent variable
1Procedures excluding
explicit dynamics.
2When importing surface
fields, the fields must be written at surfaces in the
.sim file. Abaqus does not support a capability to write fields at surfaces.
Surface output to the .sim file is supported by
the SIMULIA Navier-Stokes solver (3DEXPERIENCE platformFluid Scenario Creation app).
Fields are mapped automatically when the source and target meshes are topologically
different. However, Abaqus performs a mesh check internally before importing distributions and initial
conditions, and, if the following conditions are satisfied, no mapping is performed:
All of the nodes and elements in the target region are found in the source
output database (.sim) file with matching labels.
Matching elements in the target region and the source .sim
file have the same connectivities and element types.
Source data are requested at the same location (nodes or element integration
points) where distributions are specified.
Input File Usage
Use the following options to import external fields to define
history-dependent fields:
FIELD IMPORTEXTERNAL FIELD, FILE=file name
NODES or ELEMENTS or SURFACE, target region, target quantity ID, NODES or ELEMENTS or SURFACE, source region, source quantity ID
For example,
FIELD IMPORTEXTERNAL FIELD, FILE=thermalAnalysis.sim, START TIME=0, END TIME=3600
ELEMENTS, ESTRESS, NT, ELEMENTS, ETHERMAL, NT
imports temperatures defined as nodal temperatures (NT) from output database
thermalAnalysis.sim and applies them as a nodal temperature
field in the current stress analysis. In this case the current analysis does not
have temperature degrees of freedom; therefore, temperatures are imported as a
predefined temperature field at the nodes. The temperatures are extracted from
the body defined by element set ETHERMAL in the
thermalAnalysis job and are mapped to the body defined by
element set ESTRESS in the current analysis.
Importing Field Variables and Temperature as a Field Variable
When importing field variables and temperature as a field variable, you might notice
differences when you compare the source and target fields. There are two possible
causes of these differences:
Field variables and temperature as a field variable are mapped accurately and
imported at nodes. However, when saved to the output database, these quantities
are interpolated to element integration points. When contouring, some averaging
can occur depending on the contouring parameters selected.
For fully integrated first-order elements, a selective reduced-integration
technique is employed (see Solid isoparametric quadrilaterals and hexahedra). In this case field variables and temperature as
a field variable are averaged at the element center and saved to the output
database.
The values correctly reflect the internal magnitudes used by Abaqus.
Importing Fields at a Specified Step and Increment
If you are reading from a SIM database to define distributions or initial conditions,
you can specify the step and the increment from which to extract the field values.
You must ensure that the field is saved to the SIM database at the specified step
and increment. If the increment is omitted, the values at the end of the step are
imported.
Input File Usage
Use the following option to import field values at a specified step and
increment of a previous analysis to define distribution or initial
conditions:
You can import fields at a specified snap-shot point. For a time-domain analysis, a
snap-shot point is a specified time. For a frequency-domain analysis, a snap-shot
point is a specified frequency or mode number. Frequency-domain results can be
imported only from a non-SIM database. If the snap-shot point does not coincide with
when the fields were saved, Abaqus linearly interpolates the field values between the snap-shot points available to
obtain the field values at the request time or frequency.
You can specify the analysis step. In this case the time refers to the step time to
extract field values in the output database, Otherwise, time refers to the total
time.
To import the last saved values of an analysis step or of the analysis, do not
specify any of the time or frequency parameters. This might be useful when reading
from a linear perturbation step or from a steady-state analysis where time has no
physical meaning.
Input File Usage
Use the following option to import fields at a specified time (specified as
total time):
EXTERNAL FIELD, TYPE=SNAP SHOT, FILE=file name, TIME=total time
Use the following option to import fields at a specified analysis step and
time (specified as step time):
EXTERNAL FIELD, TYPE=SNAP SHOT, STEP=analysis step, TIME=step time
Use the following option to import fields at the end of an analysis
step:
You can import fields over a specified time range when importing fields to define
history-dependent fields. You specify the start time and end time to define the time
range in the upstream analysis to import fields.
Typically, data corresponding to the time points (increments of the downstream
analysis) are not present in the output database. In this case field values are
linearly interpolated between the time points stored in the output database to
obtain values at the required time. Because the interpolation is linear, you must
ensure that sufficient data is available in the output database to achieve
sufficient accuracy.
If you are reading from a SIM database, you can specify the analysis step. In this
case the time range refers to the step time to extract field values in the output
database. Otherwise, time refers to the total time.
To import results over an analysis step or the entire analysis, do not specify a
start and end time. If you omit the end time, results are imported as follows:
If you specified an analysis step, results are imported to the end of the
analysis step.
If you omitted the analysis step, results are imported to the end of the
analysis.
Input File Usage
Use the following option to import fields over a specified time range
(specified as total time):
EXTERNAL FIELD, FILE=file name, TYPE=TIME RANGE, START TIME=start time, END TIME=end time
Use the following option to import fields over a specified time range
(specified as step time) in an analysis step:
EXTERNAL FIELD, FILE=file name, TYPE=TIME RANGE, STEP=analysis step, START TIME=start time, END TIME=step end time
Use the following option to import fields over the entire upstream
analysis:
Use the following option to import fields over a time range, starting at a
specified time to the end of the analysis:
EXTERNAL FIELD, FILE=file name, TYPE=TIME RANGE, START TIME=start time
Use the following option to import fields over a time range in a particular
analysis step, starting at a specified time to the end of the analysis
step:
EXTERNAL FIELD, FILE=file name, TYPE=TIME RANGE, STEP=analysis step, START TIME=start time, END TIME=step end time
Resolving Different Physics Time Scales
When importing fields over a time range, Abaqus performs no time scaling by default. Specifically, if the upstream analysis time
range is larger than the downstream analysis time range, Abaqus imports only the partial upstream fields. When the upstream analysis is shorter
than the downstream analysis, Abaqus keeps the last imported field values constant for the remaining duration of the
downstream analysis step.
For certain multiphysics simulations, the physics time scales might be different when
performing a sequential analysis. For example, you can perform an electromagnetic
analysis followed by a thermal-stress analysis importing heat losses. The time scale
for the electromagnetic analysis might be significantly shorter than the time scale
for conduction in the thermal-stress analysis. When the requested time range of the
upstream analysis is different from the analysis step time of the downstream
analysis, you can scale time such that the requested upstream analysis range is
mapped over the entire downstream analysis step. In this case you must provide an
end time value explicitly.
Input File Usage
Use the following option to map the upstream analysis results over the
downstream analysis step:
EXTERNAL FIELD, FILE=file name, TYPE=TIME RANGE, TIME SCALING=ON, START TIME=start time, END TIME=end time
Applying Field Mapper Controls
Typically, the source and target regions have different meshes. Fields are mapped
conservatively between the source and target meshes, and Abaqus selects the most appropriate mapping algorithm based on the field properties. For
most cases, the default settings for the mapping algorithm are adequate, but you can
modify the mapper settings by specifying field mapper controls when importing
distributions and initial conditions.
Missing members might be reported during the mapping operation. Missing members are
nodes or elements for which the mapper cannot find a correspondence between source
and target meshes. Consequently, the mapper does not compute field values at these
locations. In this case, you can modify the default search tolerances or specify how
to treat missing members. A zero value is applied automatically for missing members
when importing history-dependent flux quantities (that is, forces, pressure,
tractions, and heat fluxes) and no treatment is required.
Input File Usage
Use the following options to specify field mapper controls:
You can apply one or more field operations when importing fields.
You can scale a field by a constant value by providing a scale factor. The scaling
factor is intended to scale a field by a physical constant. It is not intended for
unit conversion; for example, where you might need additional parameters to convert
a temperature field.
You can extract a component of a vector or tensor field by providing a component
index, i. The ith
component of the source vector or tensor field is extracted and then mapped and
imported as a scalar field. The components are extracted in the local coordinate
system of the source field. You can apply component extraction when importing
distributions, initial conditions, and history-dependent fields; it cannot be used
for a submodel analysis.
If a region in the previous analysis is not colocated with the region in the current
analysis, you must specify the translation and rotation to reposition the source
region before field values are imported. You specify a rotation by giving two
points, a and b, to define a
rotation axis and a right-handed angular rotation about the axis. Local coordinate
systems defined within the source region are translated and rotated according to the
specified positioning data.
Input File Usage
Use the following options to scale a field by a constant value:
Use the following options to reposition the source region with the target
region before importing data:
FIELD OPERATIONS, NAME=field operation namex, y, zx1, y1, z1, x2, y2, z2, rotationEXTERNAL FIELD, FILE=file name
, , , , , , , field operation name
Limitations
The following limitations apply:
Volumes or surfaces defined over beam, pipe, and truss elements or edges of
shell or membrane elements cannot be used to specify the target region. When
appropriate, you should import values at nodes.
Source or target regions with the following underlying element types are not
supported: modified triangular elements, modified tetrahedral elements,
second-order temperature-displacement elements, generalized plane strain
elements, and axisymmetric shells.
Tensor fields cannot be imported from a source region with two-dimensional
elements.
Fields cannot be imported through the thickness of structural elements when
importing history-dependent fields.
Reading fields from non-SIM databases is supported only when importing
history-dependent fields; it is not supported when importing distributions and
initial conditions.
When importing fields from the same results database using multiple EXTERNAL FIELD options,
you must import all fields at a specific time or over a time range; in either
case, the time or the time range must be the same.
Because importing external fields in a sequential analysis is a general capability,