Electrical conduction in the absence of diffusion
Elements tested
DC3D8
Features tested
Electrical conduction in cardiac tissue in the absence of diffusion.
Problem description
The tests verify the electrical conduction in cardiac tissue in the absence of diffusion. In this context, the electric potential, , and recovery variable, , are the solution of
The special-purpose framework implemented in Abaqus/Standard leverages the mathematical analogy between heat and electrical conduction. In this context, we interpret thermal quantities as their electrical counterparts and run the electrical analysis of cardiac tissue as the heat transfer analysis of an analogous thermally conductive material. Therefore, the tests use single DC3D8 elements subjected to the initial condition = −50 mV and no other boundary conditions or loads. The simulation consists of a transient heat transfer analysis, which has a duration of 500 ms. A parameter table of type "ABQ_CARDIAC_ELEC_ACTIVATION" is specified with = 15 mV to record the activation time, , in SD
Table 2 lists the material properties for materials with high or low refractoriness. Because there is no diffusion, the value of the conductivity does not influence the solution. However, we specify the diffusion alongside the specific heat and density because Abaqus/Standard requires these inputs, as shown in Table 1.
Material:
The material parameters used in the tests are given below.
| Thermal conductivity | 1.0 |
| Specific heat | 1.0 |
| Density | 1.0 |
| Oscillation threshold | 0.05 |
| Refractoriness | 0.1 (high) or 0.001 (low) |
| Scaling parameter | 0.15 |
| Scaling parameter | 8.0 |
| Shape parameter | 0.2 |
| Shape parameter | 0.3 |
(The units are not important.)
Results and discussion
The electric potential, , and recovery variable, , obtained using the special-purpose material in Abaqus/Standard agree well with the corresponding results obtained using an independent numerical method. Figure 1 and Figure 2 show all the results.
Table 3 lists the activation times saved in SDV2. They are consistent with the results shown in Figure 1.
Input files
- cardiac_electrical_high_refractoriness.inp
- Electrical conduction in a material with high refractoriness in the absence of diffusion.
- cardiac_electrical_low_refractoriness.inp
- Electrical conduction in a material with low refractoriness in the absence of diffusion.
Tables
| High refractoriness | 13.5 ms |
| Low refractoriness | 11 ms |
Figures