are often used in geotechnical applications, where pore pressure continuity between
material on opposite sides of an interface must be maintained;
govern pore fluid flow across a contact interface and into a gap region for nearby
contact surfaces;
are applicable when pore pressure degrees of freedom are present on both sides of a
contact interface (if pore pressure degrees of freedom are present on only one side of a
contact interface, the surfaces are treated as impermeable);
affect the pore fluid flow normal to the contact surfaces;
can apply to small- and finite-sliding contact formulations; and
assume that there is no fluid flowing tangentially to the surface.
Contact in coupled pore fluid diffusion/stress analysis involves displacement constraints to
resist penetrations and pore fluid contact properties that influence the fluid flow. See Coupled Pore Fluid Diffusion and Stress Analysis for details on
coupled pore fluid diffusion/stress analyses. See Defining the Constitutive Response of Fluid within the Cohesive Element Gap for details on the
use of pore pressure cohesive elements as an alternative to using contact models and pore
fluid contact properties.
The pore fluid contact properties discussed in this section apply when pore pressure
degrees of freedom exist on both sides of a contact interface. In such cases the calculated
contact pressure is effective; it does not include the pore fluid pressure contribution.
If only one side of a contact interface includes pore pressure degrees of freedom, no fluid
flow into or across the contact interface occurs. In this case the reported contact pressure
represents the total pressure, including the effective structural and pore fluid pressure
contributions; but only the effective contact pressure is used for the computation of
friction.
Including Pore Fluid Properties in a Contact Property Definition
Abaqus/Standard assumes that pore fluid flows in the normal direction at a contact interface and does not
flow tangentially along the interface. Two contributions to the fluid flow into each surface
at a contact interface are generally present, as shown in Figure 1. The fluid flow into the main and secondary surface at corresponding points on the
interface are and , respectively.
One contribution () is associated with flow across the interface. A positive value of corresponds to flow out from the main surface and into the secondary
surface.
The other contribution ( for the secondary surface and for the main surface) is associated with removing or adding fluid from
the region between the surfaces while the gap distance is changing. The sign convention
is such that and are positive when these contributions flow into the respective
surfaces (while the gap width decreases). The sum of and (which is the same as the sum of and ) is equal to negative one times the rate of change of the gap width up
to the threshold distance discussed in Controlling the Distance within Which Pore Fluid Contact Properties Are Active.
In steady-state analyses the rate of separation of the surfaces is zero, so the fluid flow
contributions and are zero; all fluid flowing out of one surface flows into the other in
steady-state analyses.
Figure 1. Flow patterns in the interface contact element.
Pore fluid flow at a contact interface typically occurs even if contact permeability
characteristics are not explicitly specified in the contact property definition.
Alternatively, you can directly specify contact permeability characteristics for enhanced
control over the flow of fluid across a contact interface and the type of constraint
enforcement method.
Controlling the Distance within Which Pore Fluid Contact Properties Are Active
The models governing fluid flow across a contact interface are most appropriate for two
surfaces in contact or separated by a relatively small gap distance. By default, Abaqus assumes no fluid flow occurs once the surfaces have separated by a distance larger than
the characteristic element length of the underlying surfaces. Alternatively, you can
directly specify a cutoff gap distance beyond which no fluid flow occurs. Separate controls
are provided for the contribution of fluid flow across the interface () and the contribution of fluid flow into the interface ().
Input File Usage
Use the following option to specify a cutoff distance () for the contribution of fluid flow across the contact interface ():
where and are pore pressures at points on opposite sides of the interface. This
relationship implies that contact permeability across the interface is infinite.
Alternatively, you can specify a contact permeability, k, such that
fluid flow across a contact interface (, discussed above in Including Pore Fluid Properties in a Contact Property Definition) is
proportional to the difference in pore pressure magnitudes across the interface:
When defining k directly, define it as
where
is the contact pressure transmitted across the interface between
A and B,
is the average of the pore pressures at A and
B,
is the average of the surface temperatures at A and
B, and
is the average of any predefined field variables at A and
B.
Figure 2 shows an example of k depending on the contact pressure. Use tabular
data to specify the value of k at one or more contact pressures as
p increases. The value of k remains constant for
contact pressures outside of the interval defined by the data points. Once the surfaces have
separated, k remains at a constant value until the separation between
the surfaces exceeds the specified flow cutoff distance (see Controlling the Distance within Which Pore Fluid Contact Properties Are Active), at
which point k drops to zero.
Defining Gap Permeability to Be a Function of Predefined Field Variables
In addition to the dependencies mentioned previously, the gap permeability can be
dependent on any number of predefined field variables, . To make the gap permeability depend on field variables, at least two
data points are required for each field variable value.
The default enforcement method depends on whether the contact permeability is specified. If
contact permeability characteristics are not explicitly specified, the continuity of pore
pressure across the interface is approximated with a penalty method (large permeability) for
general contact and directly enforced for contact pairs. You can optionally specify the
penalty method for contact pairs.
If contact permeability is specified, fluid flow consistent with the specific permeability
is directly enforced for both contact pairs and general contact. If contact permeability is
specified, the penalty method is not applicable and not allowed.
You can control the constraint enforcement through contact controls, which is the
recommended method. Alternatively, you can define constraint enforcement through a surface
interaction property.
Input File Usage
To directly enforce the intended physical model for contact permeability without
approximation , use the following options (recommended method):
Heat transfer can be considered simultaneously with pore fluid flow, in which case heat
flow across the contact interface can occur in conjunction with fluid flow. These various
contact property aspects are defined with separate options as part of a single contact
property definition that you assign to the contact interaction; see Thermal Contact Properties for details on defining heat transfer
properties.
Output
You can write the contact surface variables associated with the interaction of contact
pairs to the Abaqus/Standard data (.dat), results (.fil), and output
database (.odb) files. In addition to the surface variables associated
with the mechanical contact analysis (shear stresses, contact pressures, etc.) several pore
fluid-related variables (such as pore fluid volume flux per unit area) on the contact
interface can be reported. A detailed discussion of these output requests can be found in
Surface Output from Abaqus/Standard and Writing Surface Output to the Output Database.
Abaqus/Standard provides the following output variables related to the pore fluid interaction of
surfaces:
PFL
Pore volume flux per unit area leaving the secondary surface.
PFLA
PFL multiplied by the area
associated with the secondary node.
PTL
Time integrated PFL.
PTLA
Time integrated PFLA.
TPFL
Total pore volume flux leaving the secondary surface.