ProductsAbaqus/StandardAbaqus/ExplicitAbaqus/CAE
TypeModel data
LevelModel
Abaqus/CAEInteraction module
Optional parameters
- COMPONENT
Set this parameter equal to the connector's component of relative motion for which a connector
damage initiation criterion is specified. See Connection Types for components of relative
motion definitions. If this parameter is used, the CONNECTOR POTENTIAL option
cannot be used in conjunction with the CONNECTOR DAMAGE INITIATION
option.
Omit this parameter and use the
CONNECTOR POTENTIAL option in conjunction with the
CONNECTOR DAMAGE INITIATION option to
specify a connector damage initiation criterion involving several components of
relative motion.
- CRITERION
Set CRITERION=FORCE (default) to specify a damage initiation criterion based on
total forces/moments in the connector.
Set CRITERION=MOTION to specify a damage initiation criterion based on relative
displacements/rotations in the connector.
Set CRITERION=PLASTIC MOTION to specify a damage initiation criterion based on the
equivalent plastic relative motion as defined by the associated plasticity
definition. If CRITERION=PLASTIC MOTION, the
CONNECTOR POTENTIAL option cannot be used in conjunction with the
CONNECTOR DAMAGE INITIATION option.
- DEPENDENCIES
Set this parameter equal to the number of field variable dependencies
included in the definition of the connector damage initiation criterion, in
addition to temperature. If this parameter is omitted, it is assumed that the
connector damage initiation criterion is independent of field variables.
See Material Data Definition for more information.
- EXTRAPOLATION
Set EXTRAPOLATION=CONSTANT (default unless
CONNECTOR BEHAVIOR, EXTRAPOLATION=LINEAR is used) to use constant extrapolation of the dependent
variables outside the specified range of the independent variables.
Set EXTRAPOLATION=LINEAR to use linear extrapolation of the dependent variables outside
the specified range of the independent variables.
- RATE FILTER FACTOR
This parameter applies only to
Abaqus/Explicit
analyses.
Set this parameter equal to the factor to be used for filtering the
equivalent relative plastic motion rate for the evaluation of rate-dependent
connector damage initiation data. The default value is
0.9.
- RATE INTERPOLATION
This parameter applies only to
Abaqus/Explicit
analyses and is used only to interpolate rate-dependent connector damage
initiation data.
Set RATE INTERPOLATION=LINEAR (default) to use linear intervals for the equivalent relative
plastic motion rate while interpolating rate-dependent damage initiation data.
Set RATE INTERPOLATION=LOGARITHMIC to use logarithmic intervals for the equivalent relative
plastic motion rate while interpolating rate-dependent damage initiation data.
- REGULARIZE
This parameter applies only to
Abaqus/Explicit
analyses.
Set REGULARIZE=ON (default unless
CONNECTOR BEHAVIOR, REGULARIZE=OFF is used) to regularize the user-defined tabular connector
damage initiation data.
Set REGULARIZE=OFF to use the user-defined tabular connector damage initiation
data directly without regularization.
- RTOL
This parameter applies only to
Abaqus/Explicit
analyses.
Set this parameter equal to the tolerance to be used to regularize the
connector damage initiation data.
If this parameter is omitted, the default is RTOL=0.03 unless the tolerance is
specified on the
CONNECTOR BEHAVIOR option.
Data lines for CRITERION=FORCE
- First
line
Lower (compression) limiting force or moment. If not specified, no lower
limit is used.
Upper (tension) limiting force or moment. If not specified, no upper limit
is used.
Temperature.
First field variable.
Second field variable.
Etc., up to five field variables.
- Subsequent lines (only needed if the DEPENDENCIES parameter has a value greater than five)
Sixth field variable.
Etc., up to eight field variables per line.
Repeat this set of data lines as often as necessary to
define the connector damage initiation limiting values as a function of
temperature and other predefined field
variables.
Data lines for CRITERION=MOTION
- First
line
Lower (compression) limiting connector constitutive relative displacement or
rotation. If not specified, no lower limit is used.
Upper (tension) limiting connector constitutive relative displacement or
rotation. If not specified, no upper limit is used.
Temperature.
First field variable.
Second field variable.
Etc., up to five field variables.
- Subsequent lines (only needed if the DEPENDENCIES parameter has a value greater than five)
Sixth field variable.
Etc., up to eight field variables per line.
Repeat this set of data lines as often as necessary to
define the connector damage initiation limiting values as a function of
temperature and other predefined field
variables.
Data lines for CRITERION=PLASTIC MOTION
- First
line
Relative equivalent plastic displacement/rotation at which damage will be
initiated.
Leave blank if the COMPONENT
parameter is specified.
Otherwise, mode mix ratio. See Mode Mix Ratio for
information on how this quantity is defined.
Relative equivalent plastic displacement/rotation rate.
Temperature.
First field variable.
Second field variable.
Etc., up to four field variables.
- Subsequent lines (only needed if the DEPENDENCIES parameter has a value greater than four)
Fifth field variable.
Etc., up to eight field variables per line.
Repeat this set of data lines as often as necessary to define the connector
damage initiation criterion as a function of mode mix ratio, equivalent plastic motion rate,
temperature, and other predefined field variables.