ProductsAbaqus/StandardAbaqus/ExplicitAbaqus/CAE
TypeHistory data
LevelStep
Abaqus/CAESupported in the
Step module; only one adaptive mesh
domain can be defined per step.
At least one of the following parameters is required
- ELSET
-
Set this parameter equal to the name of the element set that contains all
the solid elements in the adaptive mesh domain.
- OP
-
Set OP=MOD (default) to modify the frequency and intensity of adaptive
meshing for an existing adaptive mesh domain (with the same element set name)
or to define a new adaptive mesh domain.
Set OP=NEW if all adaptive mesh domains that are currently in effect
should be removed. To remove only selected adaptive mesh domains, use OP=NEW and respecify all adaptive mesh domains that are to be
retained.
The OP parameter must be the same for all uses of the
ADAPTIVE MESH option within a single step.
Optional parameters
- CONTROLS
-
Set this parameter equal to the name of the
ADAPTIVE MESH CONTROLS option associated with this adaptive mesh domain. Adaptive
mesh controls can be used to control the adaptive meshing in explicit dynamic
analysis and in implicit acoustic analysis and to control the advection
algorithms applied to the adaptive mesh domain in explicit dynamic analysis.
- FREQUENCY
-
Set this parameter equal to the frequency in increments at which adaptive
meshing is to be performed. When the option is used in a spatial mesh
constraint or an Eulerian boundary region is defined on the adaptive mesh
domain in explicit dynamic analysis, the default frequency is 1. A default
frequency of 1 is also used for acoustic domains. In all other cases the
default frequency is 10.
- INITIAL MESH SWEEPS
-
This parameter applies only to
Abaqus/Explicit
analyses.
Set this parameter equal to the number of mesh sweeps to be performed at the
beginning of the first step in which this adaptive mesh definition is active.
The default number of initial mesh sweeps is 5 if
ADAPTIVE MESH CONTROLS, SMOOTHING OBJECTIVE=UNIFORM is used. The default number of initial mesh sweeps is 2 if
ADAPTIVE MESH CONTROLS, SMOOTHING OBJECTIVE=GRADED is used.
- MESH SWEEPS
-
Set this parameter equal to the number of mesh sweeps to be performed in each adaptive mesh
increment. The default number of mesh sweeps is 5.
There are no data lines associated with this option.