ProductsAbaqus/StandardAbaqus/ExplicitAbaqus/CAE
TypeModel data
LevelModel
Abaqus/CAEProperty module
Optional, mutually exclusive parameters
- BULK MODULUS
-
Include this parameter to define the bulk modulus for the acoustic medium
(default).
- CAVITATION LIMIT
-
This parameter applies only to
Abaqus/Explicit
analyses.
Include this parameter to define the cavitation pressure limit for the
acoustic medium. When the fluid absolute pressure drops to this limit, the
acoustic medium undergoes free volume expansion or cavitation without a further
decrease in the pressure. A negative cavitation limit value represents an
acoustic medium that is capable of sustaining a negative absolute pressure up
to the specified limit value. Any nonzero initial acoustic static pressure
values such as those due to the atmospheric pressure and/or the hydrostatic
loading can be specified using the
INITIAL CONDITIONS, TYPE=ACOUSTIC STATIC PRESSURE option.
If this parameter is omitted, the fluid is assumed not to cavitate even
under arbitrarily large negative pressure conditions.
- COMPLEX BULK MODULUS
-
Include this parameter to define the complex bulk modulus for the acoustic
medium.
- COMPLEX DENSITY
-
Include this parameter to define the complex density for the acoustic
medium.
- POROUS MODEL
-
This parameter applies only to
Abaqus/Standard
analyses.
Set POROUS MODEL=DELANY BAZLEY or DELANY-BAZLEY (default) to use the Delany-Bazley model to compute the
frequency-dependent complex density and the complex bulk modulus.
Set POROUS MODEL=MIKI to use the Delany-Bazley-Miki model to compute the
frequency-dependent complex density and the complex bulk modulus.
Set POROUS MODEL=BIOT-JOHNSON to use the model of Biot and Johnson et al. to compute the
frequency-dependent properties of the coupled poroelastic acoustic material.
Set POROUS MODEL=BIOT-ATALLA to use the coupled poroelastic-acoustic material model of Biot
and Atalla et al. together with the COMPLEX BULK MODULUS and COMPLEX DENSITY parameters specified as separate options.
- VOLUMETRIC DRAG
-
Include this parameter to define the volumetric drag coefficient for the
acoustic medium.
Optional parameters
- DEPENDENCIES
-
Set this parameter equal to the number of field variable dependencies
included in the definition of the acoustic medium, in addition to temperature.
If this parameter is omitted, it is assumed that the acoustic medium property
is constant or depends only on temperature.
See Material Data Definition for more information.
Data lines
to define the bulk modulus of an acoustic material
- First line
-
Bulk modulus. (Units of FL−2.)
-
Temperature.
-
First field variable.
-
Second field variable.
-
Etc., up to six field variables.
- Subsequent lines (only needed if the DEPENDENCIES parameter has a value greater than six)
-
Seventh field variable.
-
Etc., up to eight field variables per line.
Repeat this set of data
lines as often as necessary to define the bulk modulus as a function of
temperature and other predefined field
variables.
Data lines
to define the cavitation pressure limit of an acoustic material
- First line
-
-
Cavitation pressure limit. (Units of FL−2.)
-
Temperature.
-
First field variable.
-
Second field variable.
-
Etc., up to six field variables.
- Subsequent lines (only needed if the DEPENDENCIES parameter has a value greater than six)
-
Seventh field variable.
-
Etc., up to eight field variables per line.
Repeat this set of data
lines as often as necessary to define the cavitation pressure limit as a
function of temperature and other predefined field
variables.
Data line to
define the complex bulk modulus of an acoustic material
- First line
-
-
Real part of the bulk modulus. (Units of FL−2.)
-
Imaginary part of the bulk modulus. (Units of
FL−2.)
-
Frequency. (Units of T−1.)
Repeat this data line as
often as necessary to define the complex bulk modulus as a function of
frequency.
Data line to
define the complex density of an acoustic material
- First line
-
Real part of the density. (Units of ML−3.)
-
Imaginary part of the density. (Units of ML−3.)
-
Frequency. (Units of T−1.)
Repeat this data line as
often as necessary to define the complex density as a function of
frequency.
Data lines
to define the volumetric drag of an acoustic material
- First line
-
-
Volumetric drag coefficient. (Units of FTL−4.)
-
Frequency. (Cycles/time.) Frequency dependence is active only during
frequency domain procedures in
Abaqus/Standard.
-
Temperature.
-
First field variable.
-
Second field variable.
-
Etc., up to five field variables.
- Subsequent lines (only needed if the DEPENDENCIES parameter has a value greater than five)
-
Sixth field variable.
-
Etc., up to eight field variables per line.
Repeat this set of data
lines as often as necessary to define the volumetric drag as a function of
frequency, temperature, and other predefined field
variables.
Data line
when POROUS MODEL=DELANY BAZLEY, DELANY-BAZLEY, or MIKI
- First (and
only) line
-
Flow resistivity. (Units of FTL−4.)
Data line
when POROUS MODEL=BIOT-ATALLA
- First (and
only) line
-
Fluid density. (Units of ML−3.)
-
Tortuosity. (Dimensionless.)
-
Structural material bulk modulus. (Units of FL−2.)
-
Fluid-structure coupling factor. (Dimensionless, default=1.)
Data lines
when POROUS MODEL=BIOT-JOHNSON
- First
line
-
Fluid density. (Units of ML−3.)
-
Tortuosity. (Dimensionless.)
-
Structural material bulk modulus. (Units of
FL−2.)
-
Fluid-structure coupling factor. (Dimensionless, default=1.)
- Second line
-
-
Static flow resistivity. (Units of FTL−4.)
-
Viscous characteristic length. (Units of L.)
-
Thermal characteristic length. (Units of L.)
-
Fluid dynamic shear viscosity. (Units of
MT−1L−1.)
-
Ambient fluid standard pressure. (Units of FL−2.)
-
Ambient fluid heat capacity ratio of the specific heat per unit mass at
constant pressure over the specific heat per unit mass at constant volume.
(Dimensionless.)
-
Prandtl number, the ratio of viscous diffusion rate over the thermal