Specify the Shell thickness.
-
Choose Value, and enter a value for the shell
thickness. In continuum shells this value is used to estimate certain section
properties, such as hourglass stiffness, which are later computed using the
actual thickness computed from the element geometry.
-
Choose Element distribution; and select
either an analytical field, labeled with an (A), or an element-based discrete
field, labeled with a (D), to define a spatially varying element-based shell
thickness. Alternatively, you can click
to create a new analytical field or click
to create a new discrete field. See
The Analytical Field toolset
and
The Discrete Field toolset
for more information.
-
Choose Nodal distribution; and select either
an analytical field, labeled with an (A), or a node-based discrete field,
labeled with a (D), to define a spatially varying node-based shell thickness.
Alternatively, you can click
to create a new analytical field or click
to create a new discrete field. See
The Analytical Field toolset
and
The Discrete Field toolset
for more information.
-
Select a material for the shell section. If desired, click
to create a material; see
Creating or editing a material,
for more information. Linear or nonlinear material behavior can be associated
with the section definition. However, if the material response is linear, a
more economical approach is to use a generalized shell section.
-
If you are specifying properties for homogeneous shell sections
integrated before the analysis, you can specify an
Idealization to apply to the section based on assumptions
about the expected behavior of the shell. For more information, see
Idealizing the Section Response.
-
Select No idealization to account for the
complete stiffness of the shell section as determined from the material
assignment.
-
Select Membrane only if the predominant
response of the shell will be in-plane stretching; bending stiffness terms are
eliminated from the shell stiffness calculations.
-
Select Bending only if the predominant
response of the shell will be pure bending; membrane stiffness terms are
eliminated from the shell stiffness calculations.
-
If you are specifying properties for homogeneous shell sections
integrated during the analysis, select the Thickness integration
rule.
See
Defining the Shell Section Integration,
for more information.
-
If you are specifying properties for homogeneous shell sections
integrated during the analysis, enter the number of thickness integration
points. The default number of integration points through the thickness is 5 for
Simpson's rule integration and 3 for Gauss quadrature integration. To specify a
new value for the number of integration points, you can type the number
directly or click the arrows in the Thickness integration
points text field.
-
If you are using the Simpson integration
rule, you can specify only odd numbers ranging from 3 to 15.
-
If you are using the Gauss integration rule,
you can specify numbers ranging from 2 to 15.
|