Display the predefined field variable editor using one of the
following methods:
-
To create a new predefined field variable, follow the procedure
outlined in
Creating predefined fields
(Category: Other ;
Types for Selected Step:
Field ).
Note:
If you want to specify the field variable variation directly
in the editor, in user subroutine
UFIELD or
VUFIELD, or using an analytical field or discrete field, you must
select a region for the field variable. If you want to specify any other field
distribution, you can click Done in the prompt area to
use calculated fields.
-
To edit an existing field variable using menus or managers, see
Editing step-dependent objects.
-
If you are editing a field variable in any general analysis step other
than the one in which the field variable was created, click the arrow to the
right of the Status field, and select the option of your
choice from the list that appears:
-
Select Propagated to indicate that the field
variable is active in the current step with field variable values held constant
from the previous step. No data can be specified; click
OK to exit the editor. If you change the status of the
current step from Modified to
Propagated and click OK, all
modifications to the current step are removed.
-
Select Modified to edit the field variable
definition for the current step. Continue with Step 3.
-
Select Reset to initial to reset the field
variable definition to the one that was prescribed in the initial step. No data
can be specified; click OK to reset the field and to
exit the editor.
-
If you are creating a new field variable, click the arrow to the right
of the Distribution field, and select the option of your
choice from the list that appears.
Note:
If you are creating a field variable in the initial step, only the
Direct specification, From results or output
database file, analytical field, and discrete field distribution
options are available.
-
Select Direct specification to specify the
field variable variation over the selected region in the field editor.
-
Select From results or output database file
to read field variable values from the results or output database file of a
previous
Abaqus
analysis.
-
Select User-defined to define field variable
values in user subroutine
UFIELD for
Abaqus/Standard
analyses or user subroutine
VUFIELD for
Abaqus/Explicit
analyses. See
Specifying general job settings
for more information.
-
Select From results or output database file and
user-defined to read field variable values from the results or
output database file of a previous
Abaqus
analysis and modify them in user subroutine
UFIELD or
VUFIELD.
-
Select an analytical field, labeled with an (A), or a discrete
field, labeled with a (D), to define a spatially varying field variable. The
selection list contains all analytical fields and only discrete fields that are
valid for the field variable.
Alternatively, you can click
to create a new analytical field. (See
The Analytical Field toolset
for more information.)
-
If you selected the Direct specification,
analytical field, or discrete field distribution option, perform the following
steps:
-
Click the arrows to right of the Field variable
number field to indicate the number of the field variable you are
defining.
-
Click the arrow to the right of the Section
variation field, and select an option from the list that appears.
Only options that are valid for the selected region appear in the list. Beam
and shell gradient values are not affected by an analytical field or a discrete
field. You should select an option that is consistent with the field variable
variation method defined in the section definition associated with the region
selected for this field variable as follows:
-
Select Constant through region to define
a constant field variable value over a section.
In the Magnitude text field, enter the
magnitude of the field variable across the section.
-
Select Gradient through beam section to
define the field variable variation through a beam section. (This method is not
available for axisymmetric models.)
In the Reference magnitude text field,
enter the magnitude of the field variable at the cross-section origin. In the
N2 gradient text field, enter the field variable gradients
through the section in the -direction
of the beam.
-
Select Defined at shell/beam field points
to define a piecewise linear field variable variation through a shell or beam
section.
Select the number of field points to be specified by either
typing an integer in the Field points text field or using
the arrows to the right of the text field to select a number, and enter the
magnitude of the field variable at each point in the Section
Data table. The number of values in the section definition should be
less than or equal to the number of field variable data points given for this
field. If the number of values is less, the last value will be repeated to
match the number of field variable data points.
-
If desired (for all steps other than the initial step), click the
arrow to the right of the Amplitude text field, and select
the amplitude of your choice from the list that appears. Alternatively, you can
click
to create a new amplitude. (See
The Amplitude toolset
for more information.) Beam and shell gradient values will be modified by the
amplitude definition.
-
Click OK to save your data and to exit the
editor.
-
If you selected the From results or output database
file distribution option, perform the following steps:
-
Click the arrows to the right of the Field variable
number field to indicate the number of the field variable you are
defining. The default is field variable number 1. To define more than one field
variable, you can create additional predefined fields. You must number the
field variables consecutively starting from 1.
-
In the File name text field, enter the name
of the results or output database file from which field variable data are to be
read; or click
to display the Select Results or Output Database
File dialog box and select the file of your choice. (See
Using file selection dialog boxes
for more information.)
-
If you are reading results from an output database in an
Abaqus/Standard
analysis, you can specify a scalar nodal output variable to be read and used to
initialize the field variable.
-
If you are creating a field variable in the initial step:
-
In the Step text field, enter the step
number of the analysis whose results or output database file is being used as
input from which the field variable data should be read.
-
In the Increment text field, enter the
increment number of the analysis whose results or output database file is being
used as input from which the field variable data should be read.
-
Optionally, if you are creating a field variable in an analysis
step other than the initial step:
-
In the Begin step text field, enter the
step number of the analysis whose results or output database file is being used
as input that begins the field variable data to be read. By default, the first
step available in the results or output database file is used.
-
In the Begin increment text field, enter
the increment number of the analysis whose results or output database file is
being used as input that begins the field variable data to be read. By default,
the first increment available in the results or output database file is used.
-
In the End step text field, enter the
step number of the analysis whose results or output database file is being used
as input that ends the field variable data to be read. By default, the
Begin step value is used.
-
In the End increment text field, enter
the increment number of the analysis whose results or output database file is
being used as input that ends the field variable data to be read. By default,
the last increment available for the End step value in the
results or output database file is used.
-
Choose the Mesh compatibility.
-
Select Compatible if the meshes in the
original analysis and the current analysis are the same or differ only in the
element order.
-
Select Incompatible if the meshes in the
original analysis and the current analysis are dissimilar. This option is valid
only if the field variable values are being read from an output database file.
-
Click OK to save your data and to exit the
editor.
-
If you selected the User-defined distribution
option, perform the following steps:
-
Click OK to exit the editor.
-
Enter the
Job module,
and display the job editor for the analysis job of interest. (For more
information, see
Creating, editing, and manipulating jobs.)
-
In the job editor, click the General tab, and
specify the file containing the user subroutine that defines the field variable
values. For more information, see
Specifying general job settings.
Note:
You can specify only one user subroutine file in the job editor;
if your analysis involves more than one user subroutine, you must combine the
user subroutines into one file and then specify that file.
-
If you selected the From results or output database file and
user-defined distribution option, follow the procedures outlined in
Steps 5 and 6 for the From results or output database file
and User-defined distribution options.
|