Time Incrementation Parameters and Adjustment Criteria
Table 1 lists tolerance parameters available for specific analysis procedures. Descriptions of time integrators for the transient procedure types and, in the case of implicit dynamics, discussion of additional factors influencing the time increment size related to accuracy of time integration are provided in the respective sections referenced in Table 1.
Procedure | Accuracy measure | Tolerance |
Implicit dynamics (Implicit Dynamic Analysis Using Direct Integration) | Half-increment residual | Half-increment residual tolerance |
Transient heat transfer analysis (Uncoupled Heat Transfer Analysis) | Temperature increment, | |
Consolidation analysis (Coupled Pore Fluid Diffusion and Stress Analysis) | Pore pressure increment, | |
Creep and viscoelastic material behavior (Rate-Dependent Plasticity: Creep and Swelling) | Creep tolerance |
In any transient analysis where automatic time incrementation is used, some of these tolerances, , , will be active. Corresponding measures of the integration accuracy, , will be calculated for each increment in the step. Abaqus/Standard will use these values to adjust the time incrementation using the criteria described in this section. The smallest time increment required by all criteria is used if more than one accuracy measure is active.
Reducing the Time Increment Size
If for any control, J, that is active in the step, the time increment is too large to satisfy that time integration accuracy requirement. The increment is, therefore, begun again with a time increment of
where you can define the value of . By default, = 0.85.
Increasing the Time Increment Size
If at the current time increment, ,
for all J in each of consecutive increments, i, and if no cut-back has occurred within those increments because of nonlinearity, the next time increment will be increased to
You can define the values of , , and . By default, = 3, = 0.75, and = 0.8. is the proposed new time increment, which is defined as
for transient heat transfer and transient mass diffusion problems and which is defined as
for other transient problems.
A limit, , is placed on the time increment increase factor. The default value of depends on the type of analysis:
= 1.25 for dynamic analysis
= 2.0 for diffusion-dominated processes: creep, transient heat transfer, coupled temperature-displacement, soils consolidation, and transient mass diffusion
= 1.5 for all other cases
You can redefine for each analysis type.
If the problem is nonlinear, the time increment may be restricted by the rate of convergence of the nonlinear equations. The time incrementation controls used with nonlinear problems are described in Convergence Criteria for Nonlinear Problems.