Products
Abaqus/Standard
Abaqus/CAE
Type
History data
LevelStep
Abaqus/CAE
Interaction module
Optional parameters
-
AXISYMMETRIC ACCURACY
-
Use this parameter to control the accuracy of the view factor
calculations in an axisymmetric analysis.
Set
AXISYMMETRIC ACCURACY=MODERATE
to calculate the view factors with moderate accuracy.
Set
AXISYMMETRIC ACCURACY=STRICT
(default) to calculate the view factors with high accuracy by increasing
the number of integration intervals in the circumferential
direction.
-
BLOCKING
-
Set
BLOCKING=ALL
(default) to specify that full blocking checks be performed in the view
factor calculations.
Set
BLOCKING=NO
to specify that no blocking checks be performed in the view factor
calculations.
Set
BLOCKING=PARTIAL
to specify that partial blocking checks be performed in the view factor
calculations. The data lines are then used to specify the potential
blocking surfaces.
-
CAVITY
-
Set this parameter equal to the name of the cavity for which radiation
view factor control is being specified. If this parameter is omitted,
the specification applies to all cavities defined in the model.
-
INFINITESIMAL
-
Set this parameter equal to the facet area ratio above which the
infinitesimal-to-finite area approximation is used for view factor
calculations. The default value is 64.0.
-
INTEGRATION
-
Set this parameter equal to the number of Gauss integration points to be
used along each edge when the numerical integration of contour integrals
is used for view factor calculations. One to five integration points are
allowed. The default value is three integration points.
-
LUMPED AREA
-
Set this parameter equal to the nondimensional distance-square value
above which the lumped area approximation is used for view factor
calculations. The default value is 5.0.
-
OFF
-
Include this parameter to switch off cavity radiation effects. Cavity
radiation effects can be switched on again by a subsequent use of this
option without the OFF
parameter. If this parameter is omitted, cavity radiation is active.
-
RANGE
-
Set this parameter equal to a distance beyond which view factors need not
be calculated because surfaces are judged to be too far apart to “see”
each other (due to blocking by other surfaces).
-
REFLECTION
-
Set
REFLECTION=YES
(default) to indicate that reflection must be included in the cavity
radiation calculations.
Set
REFLECTION=NO
to indicate that reflection is to be ignored in the cavity radiation
calculations. No reflection corresponds to the special case of
black body radiation (see Cavity radiation).
-
SYMMETRY
-
Include this parameter to indicate the existence of radiation symmetries
in the model. This parameter must be set equal to the name appearing in
the RADIATION SYMMETRY
option where the symmetries are defined. If this parameter is omitted,
it is assumed that there are no radiation symmetries in the cavity.
-
VTOL
-
Set this parameter equal to the acceptable tolerance for the view factor
calculations. If this parameter is omitted, the default view factor
tolerance is 0.05.
Optional parameters (for use with the
MOTION option)
-
MDISP
-
Set this parameter equal to the maximum allowable motion of any node in
the monitored node set before recalculation of radiation view factors.
This parameter is relevant only when the MOTION option
appears in conjunction with the RADIATION VIEW FACTOR
option. This parameter must be used with the
NSET parameter.
-
NSET
-
Set this parameter equal to the name of the node set whose displacements
are to be monitored to decide when geometrical changes are significant
enough to trigger recalculation of the radiation view factors during the
step. This parameter is relevant only when the MOTION option
appears in conjunction with the RADIATION VIEW FACTOR
option. This parameter must be used with the
MDISP parameter.
Data lines to define blocking surfaces
(BLOCKING=PARTIAL)
- First line
-
List of surfaces that provide blocking inside the cavity,
up to eight surfaces per line.
Repeat this data line as often as necessary to define
partial blocking.
There are no data lines associated with this option if
BLOCKING=PARTIAL
is not specified