Products
Abaqus/Standard
Abaqus/Explicit
Abaqus/CAE
Type
Model data
LevelModel
Abaqus/CAE
Property module
Optional parameters
-
DEPENDENCIES
-
Set this parameter equal to the number of field variable dependencies included in the
definition of the stress potential coefficients in addition to temperature. If this
parameter is omitted, it is assumed that the coefficients are constant or depend only
on temperature. See Material Data Definition for more information.
-
POWER
-
This parameter can be used only in conjunction with
TYPE=BARLAT,
BARLAT2000,
BARLAT91, or
HOSFORD.
Set this parameter equal to the exponent in the potential function.
-
TYPE
-
This parameter is used to define the stress potential function.
Set
TYPE=BARLAT
to specify nonquadratic anisotropic yield using the Barlat Yld2004-18p stress
potential.
Set
TYPE=BARLAT2000
to specify nonquadratic anisotropic yield using the Barlat Yld2000-2d stress
potential.
Set
TYPE=BARLAT91
to specify nonquadratic anisotropic yield using the Barlat Yld91 stress potential.
Set
TYPE=HILL
(default) to specify quadratic anisotropic yield using the Hill stress potential.
Set
TYPE=HOSFORD
to specify nonquadratic isotropic yield using the Hosford criterion.
Set
TYPE=TRESCA
to specify nonquadratic isotropic yield using the Tresca criterion.
Data lines used to define stress ratios for the Hill stress potential
(TYPE=HILL)
- First line
-
.
.
.
.
.
.
Temperature.
First field variable.
- Subsequent lines (only needed if the
DEPENDENCIES parameter has a value
greater than one)
-
Second field variable.
Etc., up to eight field variables per line.
Repeat this set of data lines as often as necessary to define the
dependence of
on temperature and other field variables.
Data lines used to define coefficients for the Barlat Yld2004-18p stress
potential
(TYPE=BARLAT)
- First line
-
.
.
.
.
.
.
.
.
- Second line
-
.
.
.
.
.
.
.
.
- Third line
-
.
.
Temperature.
First field variable.
Second field variable.
Etc., up to five field variables.
- Subsequent lines (only needed if the
DEPENDENCIES parameter has a value
greater than five)
-
Sixth field variable.
Etc., up to eight field variables per line.
Repeat this set of data lines as often as necessary to define the
dependence of
and
on temperature and other field variables.
Data lines used to define coefficients for the Barlat Yld2000-2d stress
potential
(TYPE=BARLAT2000)
- First line
-
.
.
.
.
.
.
.
.
- Second line (leave blank if no temperature or field variables are
specified)
-
Temperature.
First field variable.
Etc., up to seven field variables per line.
Repeat this set of data lines as often as necessary to define the
material constants as a function of temperature and other predefined field
variables.
Data lines used to define coefficients for the Barlat Yld91 stress potential
(TYPE=BARLAT91)
- First line
-
.
.
.
.
.
.
Temperature.
First field variable.
- Subsequent lines (only needed if the
DEPENDENCIES parameter has a value
greater than one)
-
Second field variable.
Etc., up to eight field variables per line.
Repeat this set of data lines as often as necessary to define the
dependence of
,
,
,
,
, and
on temperature and other field variables.
There are no data lines associated with the Hosford stress potential
(TYPE=HOSFORD)
or the Tresca stress potential
(TYPE=TRESCA)