*MULLINS EFFECT

Specify Mullins effect material parameters for elastomers.

This option is used to define material constants for the Mullins effect in filled rubber elastomers or for modeling energy dissipation in elastomeric foams. It can be used only with the HYPERELASTIC or the HYPERFOAM options.

This page discusses:

See Also
*BIAXIAL TEST DATA
*PLANAR TEST DATA
*UNIAXIAL TEST DATA
In Other Guides
Hyperelastic Behavior of Rubberlike Materials
Hyperelastic Behavior in Elastomeric Foams
Stress Softening in Rubberlike Materials
Stress Softening in Elastomeric Foams
UMULLINS
VUMULLINS

Products Abaqus/Standard Abaqus/Explicit Abaqus/CAE

Type Model data

LevelModel

Abaqus/CAE Property module

Required parameters

DEFINITION

Set DEFINITION=OGDEN-ROXBURGH to choose the Ogden-Roxburgh model.

Set DEFINITION=EXPONENTIAL to choose that the damage variable is defined using the exponential form.

Set DEFINITION=SLOW DECAY to choose that the damage variable is defined using the slow decay form.

Set DEFINITION=USER to choose that the damage variable is defined in user subroutine UMULLINS in Abaqus/Standard or VUMULLINS in Abaqus/Explicit.

Optional parameters

BETA

This parameter can be used only when the TEST DATA INPUT parameter is used; it defines the value of β while the other coefficients of the Mullins effect model are fitted from the test data. It cannot be specified if both the R and M parameters are also specified (use the data line instead to specify all three parameters). If this parameter is omitted, β will be determined from a nonlinear, least-squares fit of the test data. Allowable values of BETA are β ≥ 0 . The M and BETA parameters cannot both be zero.

DEPENDENCIES

Set this parameter equal to the number of field variables, in addition to temperature, on which the material parameters depend. If this parameter is omitted, it is assumed that the material parameters are constant or depend only on temperature. See Material Data Definition for more information.

This parameter is not relevant if the DEFINITION=USER or the TEST DATA INPUT parameter is included.

M

This parameter can be used only when the TEST DATA INPUT parameter is used; it defines the value of m while the other coefficients of the Mullins effect model are fitted from the test data. It cannot be specified if both the R and BETA parameters are also specified (use the data line instead to specify all three parameters). If this parameter is omitted, m will be determined from a nonlinear, least-squares fit of the test data. Allowable values of M are m ≥ 0 . The M and BETA parameters cannot both be zero.

PROPERTIES

This parameter can be used only if the DEFINITION=USER parameter is specified. Set this parameter equal to the number of property values needed as data in user subroutine UMULLINS in Abaqus/Standard or VUMULLINS in Abaqus/Explicit. The default value is 0.

R

This parameter can be used only when the TEST DATA INPUT parameter is used; it defines the value of r while the other coefficients of the Mullins effect model are fitted from the test data. It cannot be specified if both the M and BETA parameters are also specified (use the data line instead to specify all three parameters). If this parameter is omitted, r will be determined from a nonlinear, least-squares fit of the test data. Allowable values of R are r > 1 .

TEST DATA INPUT

This parameter is relevant only for DEFINITION=OGDEN-ROXBURGH.

Include this parameter if the material constants are to be computed by Abaqus from data taken from simple tests on a material specimen. If this parameter is omitted, the material constants can be given directly on the data lines.

To define the material behavior for the Ogden-Roxburgh model by giving test data

No data lines are used with this option when the TEST DATA INPUT parameter is specified. The data are given instead under the BIAXIAL TEST DATA, PLANAR TEST DATA, and UNIAXIAL TEST DATA options. These options are applicable except for the case where the damage variable is defined by the user.

Data lines to define the material constants if the DEFINITION=OGDEN-ROXBURGH parameter is specified, and the TEST DATA INPUT parameter is omitted

First line
  1. r.

  2. m. (Units of FL–2.)

  3. β (If this entry is left blank, the default value is taken to be 0.0 in Abaqus/Standard and 0.1 in Abaqus/Explicit.)

  4. Temperature.

  5. First field variable.

  6. Etc., up to four field variables.

Subsequent lines (only needed if the DEPENDENCIES parameter has a value greater than four)
  1. Fifth field variable.

  2. Etc., up to eight field variables per line.

Repeat this set of data lines as often as necessary to define the material constants as a function of temperature and other predefined field variables.

Data lines to define the material properties if the DEFINITION=USER parameter is specified

No data lines are needed if the PROPERTIES parameter is omitted or set to 0. Otherwise, first line
  1. Material properties, eight per line.

Repeat this data line as often as necessary to define the material properties.

Data lines to define the material constants if the DEFINITION=EXPONENTIAL parameter is specified

First line
  1. η F .
  2. U h . (Units of FL-2.)

  3. α .

  4. Temperature.

  5. First field variable.

  6. Etc., up to four field variables.

Subsequent lines (only needed if the DEPENDENCIES parameter has a value greater than four)
  1. Fifth field variable.

  2. Etc., up to eight field variables per line.

Repeat this set of data lines as often as necessary to define the material constants as a function of temperature and other predefined field variables.

Data lines to define the material constants if the DEFINITION=SLOW DECAY parameter is specified

First line
  1. η F .
  2. U h . (Units of FL-2.)

  3. α .

  4. Temperature.

  5. First field variable.

  6. Etc., up to four field variables.

Subsequent lines (only needed if the DEPENDENCIES parameter has a value greater than four)
  1. Fifth field variable.

  2. Etc., up to eight field variables per line.

Repeat this set of data lines as often as necessary to define the material constants as a function of temperature and other predefined field variables.