Products
Abaqus/Standard
Abaqus/Explicit
Abaqus/CAE
Type
Model data
LevelModel
Abaqus/CAE
Property module
Required parameters
-
DEFINITION
-
Set
DEFINITION=OGDEN-ROXBURGH
to choose the Ogden-Roxburgh model.
Set
DEFINITION=EXPONENTIAL
to choose that the damage variable is defined using the exponential form.
Set
DEFINITION=SLOW DECAY
to choose that the damage variable is defined using the slow decay form.
Set
DEFINITION=USER
to choose that the damage variable is defined in user subroutine UMULLINS in Abaqus/Standard or VUMULLINS in Abaqus/Explicit.
Optional parameters
-
BETA
-
This parameter can be used only when the
TEST DATA INPUT parameter is used;
it defines the value of
while the other coefficients of the Mullins effect model are fitted
from the test data. It cannot be specified if both the
R and
M parameters are also specified (use
the data line instead to specify all three parameters). If this parameter is omitted,
will be determined from a nonlinear, least-squares fit of the test
data. Allowable values of BETA are
. The M and
BETA parameters cannot both be zero.
-
DEPENDENCIES
-
Set this parameter equal to the number of field variables, in addition to
temperature, on which the material parameters depend. If this parameter is omitted, it
is assumed that the material parameters are constant or depend only on temperature.
See Material Data Definition for more information.
This parameter is not relevant if the
DEFINITION=USER
or the TEST DATA INPUT parameter is
included.
-
M
-
This parameter can be used only when the
TEST DATA INPUT parameter is used;
it defines the value of m while the other coefficients of the
Mullins effect model are fitted from the test data. It cannot be specified if both the
R and
BETA parameters are also specified
(use the data line instead to specify all three parameters). If this parameter is
omitted, m will be determined from a nonlinear, least-squares fit
of the test data. Allowable values of
M are
. The M and
BETA parameters cannot both be zero.
-
PROPERTIES
-
This parameter can be used only if the
DEFINITION=USER
parameter is specified. Set this parameter equal to the number of property values
needed as data in user subroutine UMULLINS in Abaqus/Standard or VUMULLINS in Abaqus/Explicit. The default value is 0.
-
R
-
This parameter can be used only when the
TEST DATA INPUT parameter is used;
it defines the value of r while the other coefficients of the
Mullins effect model are fitted from the test data. It cannot be specified if both the
M and
BETA parameters are also specified
(use the data line instead to specify all three parameters). If this parameter is
omitted, r will be determined from a nonlinear, least-squares fit
of the test data. Allowable values of
R are
.
-
TEST DATA INPUT
-
This parameter is relevant only for
DEFINITION=OGDEN-ROXBURGH.
Include this parameter if the material constants are to be computed by Abaqus from data taken from simple tests on a material specimen. If this parameter is
omitted, the material constants can be given directly on the data lines.
To define the material behavior for the Ogden-Roxburgh model by giving test
data
No data lines are used with this option when the
TEST DATA INPUT parameter is specified.
The data are given instead under the BIAXIAL TEST DATA, PLANAR TEST DATA, and UNIAXIAL TEST DATA options. These
options are applicable except for the case where the damage variable is defined by the
user.
Data lines to define the material constants if the
DEFINITION=OGDEN-ROXBURGH
parameter is specified, and the
TEST DATA INPUT parameter is
omitted
- First line
-
r.
m. (Units of FL–2.)
(If this entry is left blank, the default value is taken to be
0.0 in Abaqus/Standard and 0.1 in Abaqus/Explicit.)
Temperature.
First field variable.
Etc., up to four field variables.
- Subsequent lines (only needed if the
DEPENDENCIES parameter has a value
greater than four)
-
Fifth field variable.
Etc., up to eight field variables per line.
Repeat this set of data lines as often as necessary to define the material
constants as a function of temperature and other predefined field
variables.
Data lines to define the material properties if the
DEFINITION=USER
parameter is specified
- No data lines are needed if the
PROPERTIES parameter is omitted or set
to 0. Otherwise, first line
-
Material properties, eight per line.
Repeat this data line as often as necessary to define the material
properties.
Data lines to define the material constants if the
DEFINITION=EXPONENTIAL
parameter is specified
- First line
-
-
.
. (Units of FL-2.)
.
Temperature.
First field variable.
Etc., up to four field variables.
- Subsequent lines (only needed if the
DEPENDENCIES parameter has a value
greater than four)
-
Fifth field variable.
Etc., up to eight field variables per line.
Repeat this set of data lines as often as necessary to define the material
constants as a function of temperature and other predefined field
variables.
Data lines to define the material constants if the
DEFINITION=SLOW DECAY
parameter is specified
- First line
-
-
.
. (Units of FL-2.)
.
Temperature.
First field variable.
Etc., up to four field variables.
- Subsequent lines (only needed if the
DEPENDENCIES parameter has a value
greater than four)
-
Fifth field variable.
Etc., up to eight field variables per line.
Repeat this set of data lines as often as necessary to define the material
constants as a function of temperature and other predefined field
variables.