Step module: history output request editor: Select from list below
Selecting the Element Set for Which Total Energy Output Is Required
You can specify the element set for which total energy output is being
requested. In this case the energies are summed for all the elements in the
specified set. You cannot specify an element set for the following procedures:
Transient modal dynamic analysis
Response spectrum analysis
Random response analysis
The following energies are not available as element set quantities: ALLCCDW, ALLCCE, ALLCCEN, ALLCCET, ALLCCSD, ALLCCSDN, ALLCCSDT, ALLFC, ALLFD, ALLKL, ALLQB, ALLWK, ALLVDM, ALLHDM, and ETOTAL.
If you do not specify an element set, the total energies for the whole model
will be output. If total energy output for both the whole model and for
different element sets is desired, the energy output requests must be repeated:
once without a specified element set to request energy output for the whole
model and once for each specified element set.
You can request the preselected, procedure-specific energy output variables
described in
Preselected Output Requests.
In this case you can specify additional variables as part of the output
request.
Alternatively, you can request all energy variables applicable to the
current procedure and material type. In this case any additional variables you
specify are ignored.
Input File Usage
Use the following option to request the preselected energy
output variables: