ProductsAbaqus/StandardAbaqus/ExplicitAbaqus/CAE
TypeHistory data
LevelStep
Abaqus/CAEStep module
Optional parameters
- ELSET
-
Set this parameter equal to the name of the element set for which this
output request is being made.
- NSET
-
This parameter applies only to mode-based steady-state dynamic analyses.
Set this parameter equal to the name of the node set representing the
boundary for energy flow, power flow, radiated acoustic energy, and radiated
acoustic power computations.
- PER ELEMENT SET
-
This parameter applies only to
Abaqus/Explicit
analyses.
Include this parameter to indicate that the requested energy variables are
written to the output database for each user-defined element set
(all internal element sets, including the internal
element sets defined in
Abaqus/CAE
and the internal element sets created during the analysis, are
excluded).
- PER SECTION
-
This parameter applies only to
Abaqus/Explicit
analyses.
Include this parameter to indicate that the requested energy variables are
written to the output database for every user-defined element set that is
associated with a section definition
(all internal element sets, including the internal
element sets defined in
Abaqus/CAE
and the internal element sets created during the analysis, are
excluded).
- VARIABLE
-
Set VARIABLE=ALL to indicate that all energy variables applicable to this
procedure and material type should be written to the output database.
Set VARIABLE=PRESELECT to indicate that the default energy output variables for the
current procedure type should be written to the output database. Additional
output variables can be requested on the data lines.
If this parameter is omitted and no energy variables are specified on the
data lines, all energy variables will be written to the output database.
Data lines to
request energy output
- First
line
Specify the identifying keys for the variables to be written to the output
database. The keys are defined in Output Variables.
Repeat this data line as
often as necessary to define the energy variables to be written to the output
database.