Products
Abaqus/Standard
Type
Model data
LevelThis option is not supported in a model defined in terms of an assembly of part instances.
Required parameters
-
ELSET
-
Set this parameter equal to the name of the element set containing the
substructures for which properties are being defined.
Optional parameters
-
DISPLAY
-
Set
DISPLAY=YES
to apply the coarse substructure display representation defined at
substructure generation for the substructures for which properties are
being defined.
Set
DISPLAY=NO
(default) to disable the coarse substructure display representation in
this model for the substructures for which properties are being
defined.
-
FREQUENCY BASED
-
This parameter is relevant to frequency-based substructures.
Frequency-based substructures are used only in a direct steady-state
dynamic analysis (see Direct-Solution Steady-State Dynamic Analysis). All other analyses use conventional substructures regardless of the
availability of frequency-based substructures.
Set
FREQUENCY BASED=ALL FREQUENCIES
to use the frequency-based substructure at all frequency points of
interest. If the frequency-based substructure is not available at a
certain frequency, an operator-averaging-based approximate solution is
given at that frequency. If a frequency of interest is beyond the range
of frequencies at which the frequency-based substructure is constructed
at generation, Abaqus issues an error.
Set
FREQUENCY BASED=NO FREQUENCIES
to disable the use of the frequency-based substructure at any frequency.
The conventional substructure is used instead at all frequencies.
Set
FREQUENCY BASED=MATCHED FREQUENCIES
(default) to use the frequency-based substructure only at frequencies at
which the frequency-based substructure is constructed at generation. At
all nonmatching frequencies, the conventional substructure is used.
-
LARGE ROTATIONS
-
Set
LARGE ROTATIONS=YES
(default) to allow large rotations of the substructure in a
geometrically nonlinear analysis.
Set
LARGE ROTATIONS=NO
to suppress large rotations of the substructure in a geometrically
nonlinear analysis.
-
MONITOR
-
Set
MONITOR=YES
to monitor the substructure solution at the nodes selected during
substructure generation for the substructures for which properties are
being defined.
Set
MONITOR=NO
(default) to disable the solution monitoring.
-
POSITION TOL
-
Set this parameter equal to the tolerance on the distance between usage
level nodes and the corresponding substructure nodes. If this parameter
is omitted, the default is a tolerance of 10−4 times the
largest overall dimension within the substructure. If the parameter is
given with a value of 0.0, the position of the retained nodes is not
checked.
Data line to translate a substructure
- First (and only) line
-
-
Value of the translation to be applied in the global
X-direction.
-
Value of the translation to be applied in the global
Y-direction.
-
Value of the translation to be applied in the global
Z-direction.
Data lines to translate and/or rotate a substructure
- First line
-
-
Value of the translation to be applied in the global
X-direction.
-
Value of the translation to be applied in the global
Y-direction.
-
Value of the translation to be applied in the global
Z-direction.
Enter values of zero to apply a pure rotation.
- Second line
-
-
Global X-coordinate of point
a on the axis of rotation (see Figure 1).
-
Global Y-coordinate of point
a on the axis of rotation.
-
Global Z-coordinate of point
a on the axis of rotation.
-
Global X-coordinate of point
b on the axis of rotation.
-
Global Y-coordinate of point
b on the axis of rotation.
-
Global Z-coordinate of point
b on the axis of rotation.
-
Angle of rotation about the axis
a–b, in
degrees.
Data lines to translate and/or reflect a substructure
- First line
-
-
Value of the translation to be applied in the global
X-direction.
-
Value of the translation to be applied in the global
Y-direction.
-
Value of the translation to be applied in the global
Z-direction.
Enter values of zero to apply a pure reflection.
- Second line
-
-
Enter a blank line.
- Third line
-
-
Global X-coordinate of point
a in the plane of reflection (see Figure 2).
-
Global Y-coordinate of point
a in the plane of reflection.
-
Global Z-coordinate of point
a in the plane of reflection.
-
Global X-coordinate of point
b in the plane of reflection.
-
Global Y-coordinate of point
b in the plane of reflection.
-
Global Z-coordinate of point
b in the plane of reflection.
- Fourth line
-
-
Global X-coordinate of point
c in the plane of reflection.
-
Global Y-coordinate of point
c in the plane of reflection.
-
Global Z-coordinate of point
c in the plane of reflection.
Data lines to translate, rotate, and reflect a
substructure
- First line
-
-
Value of the translation to be applied in the global
X-direction.
-
Value of the translation to be applied in the global
Y-direction.
-
Value of the translation to be applied in the global
Z-direction.
- Second line
-
-
Global X-coordinate of point
a on the axis of rotation (see Figure 1).
-
Global Y-coordinate of point
a on the axis of rotation.
-
Global Z-coordinate of point
a on the axis of rotation.
-
Global X-coordinate of point
b on the axis of rotation.
-
Global Y-coordinate of point
b on the axis of rotation.
-
Global Z-coordinate of point
b on the axis of rotation.
-
Angle of rotation about the axis
a–b, in
degrees.
- Third line
-
-
Global X-coordinate of point
a in the plane of reflection (see Figure 2).
-
Global Y-coordinate of point
a in the plane of reflection.
-
Global Z-coordinate of point
a in the plane of reflection.
-
Global X-coordinate of point
b in the plane of reflection.
-
Global Y-coordinate of point
b in the plane of reflection.
-
Global Z-coordinate of point
b in the plane of reflection.
- Fourth line
-
-
Global X-coordinate of point
c in the plane of reflection.
-
Global Y-coordinate of point
c in the plane of reflection.
-
Global Z-coordinate of point