*INTEGRATED OUTPUT

Specify variables integrated over a surface to be written to the output database.

This option is used to write integrated quantities over a surface, such as the total force transmitted across a surface, to the output database. It must be used in conjunction with the OUTPUT, HISTORY option.

This page discusses:

See Also
*OUTPUT
*SURFACE
*INTEGRATED OUTPUT SECTION
In Other Guides
Output to the Output Database
Integrated Output Section Definition

ProductsAbaqus/StandardAbaqus/ExplicitAbaqus/CAE

TypeHistory data

LevelStep

Abaqus/CAEStep module

One of the following mutually exclusive parameters is required when the INTEGRATED OUTPUT option is used in an Abaqus/Explicit analysis

SECTION

Set this parameter equal to the name of the INTEGRATED OUTPUT SECTION (see Integrated Output Section Definition) over which this output request is being made.

SURFACE

Set this parameter equal to the name of the surface (see Element-Based Surface Definition) over which this output request is being made.

ELSET

Set this parameter equal to the name of the element set over which this output request is being made.

One of the following mutually exclusive parameters is required when the INTEGRATED OUTPUT option is used in an Abaqus/Standard analysis

SECTION

Set this parameter equal to the name of the INTEGRATED OUTPUT SECTION (see Integrated Output Section Definition) over which this output request is being made.

SURFACE

Set this parameter equal to the name of the surface (see Element-Based Surface Definition) over which this output request is being made.

Optional parameters

VARIABLE

Set VARIABLE=ALL to indicate that all integrated output variables applicable to this procedure should be written to the output database.

Set VARIABLE=PRESELECT to indicate that the default integrated output variables for the current procedure type should be written to the output database. Additional output variables can be requested on the data lines.

If this parameter is omitted, the integrated output variables for output must be specified on the data line.

Data lines to request integrated output

First line
  1. Specify the identifying keys for the output variables to be written to the output database. The keys are defined in Abaqus/Standard Output Variable Identifiers and Abaqus/Explicit Output Variable Identifiers.

Repeat this data line as often as necessary to define the list of variables to be written to the output database.