Step module: history output request editor: Select from list below
Selecting the Element Set for Which Total Energy Output Is Required
You can specify the element set for which total energy output is being requested. In this
case the energies are summed for all the elements in the specified set. You cannot specify
an element set for the following procedures:
Transient modal dynamic analysis
Response spectrum analysis
Random response analysis
The following energies are not available as element set quantities:
ALLCCDW,
ALLCCE,
ALLCCEN,
ALLCCET,
ALLCCSD,
ALLCCSDN,
ALLCCSDT,
ALLFC,
ALLFD,
ALLKL,
ALLQB,
ALLWK,
ALLVDM,
ALLHDM, and
ETOTAL.
You can request the energy output
ALLCDCOH only if viscous regularization
energy is likely generated from damage stabilization or user-specified numerical viscosity
for cohesive and enriched XFEM elements and damage
stabilization for cohesive contact.
If you do not specify an element set, Abaqus outputs the total energies for the whole model. If total energy output for both the whole
model and for different element sets is desired, you must repeat the energy output requests:
once without a specified element set to request energy output for the whole model and once
for each specified element set.
Step module: history output request editor: Domain: Set:set_name
Specifying a Contact Surface for Energy Output
You can request the viscous regularization energy output
ALLCDCOH per contact surface in a general
step by specifying a secondary or a main surface of a contact pair or a surface in the
general contact domain when using Abaqus/Standard.
Similarly, in Abaqus/Explicit you can extract the damage dissipation energy output,
ALLDMD, for each general contact surface
using the same method. You can refine this request to limit the output to interactions
between the surface and a particular secondary surface.
Input File Usage
Use the following option to restrict the output to a selected surface:
You can request the preselected, procedure-specific energy output variables described in
Preselected Output Requests. In this case you can specify additional variables as part of the output
request.
Alternatively, you can request all energy variables applicable to the current procedure and
material type. In this case any additional variables you specify are ignored.
Input File Usage
Use the following option to request the preselected energy output variables: