*MODAL DYNAMIC

Dynamic time history analysis using modal superposition.

This option is used to provide dynamic time history response as a linear perturbation procedure using modal superposition.

This page discusses:

See Also
In Other Guides
Transient Modal Dynamic Analysis

Products Abaqus/Standard Abaqus/CAE

Type History data

LevelStep

Abaqus/CAE Step module

Optional parameters

CONTINUE

Set CONTINUE=NO (default) to specify that this step is not to carry over the initial conditions from the results of the preceding step. In this case the initial displacements are zero, and the initial velocities are taken from the INITIAL CONDITIONS, TYPE=VELOCITY option if it is used; otherwise, they are zero. Step time begins at zero.

Set CONTINUE=YES to specify that this step is to carry over the initial conditions from the end of the immediately preceding MODAL DYNAMIC step or static perturbation step. If this preceding step is a MODAL DYNAMIC step, both the velocities and the displacements from the end of this step are used as the initial conditions for the current step. If this preceding step is a static perturbation step, the displacements from this step are used as the initial displacements for the current step and the initial velocities are taken from the INITIAL CONDITIONS, TYPE=VELOCITY option if it is used; otherwise, they are zero. Step time is continued from the immediately preceding MODAL DYNAMIC or static perturbation step.

SOLVER

Set SOLVER=STATE SPACE (default) to use the state space solver.

Set SOLVER=CONVENTIONAL to use the conventional solver.

Set SOLVER=FOURIER to calculate the time domain response as the inverse Fourier transform of the frequency response obtained in the preceding mode-based or subspace-based steady-state dynamic analysis step.

SSD LOAD CASE

Set this parameter equal to the name of the load case in the preceding steady-state dynamic analysis step to select the frequency response for making the inverse Fourier transform in the modal dynamic analysis step.

If this parameter is omitted, the first load case in the preceding steady-state dynamic analysis step is selected. If the loads in the steady-state dynamic analysis step are not organized into load cases, the default single load case is selected.

Data line for a transient modal dynamic analysis

First (and only) line
  1. Time increment to be used.

  2. Time period.