*FOURIER TRANSFORM CONTROLS

Specification of control parameters for Fourier transform.

This option is used to set the control parameters for both the direct and inverse Fourier transforms. It is relevant only during the transient modal dynamic or the mode-based steady-steady dynamics analysis procedures when a Fourier transform is requested.

This page discusses:

See Also
*STEADY STATE DYNAMICS
*MODAL DYNAMIC
In Other Guides
Fourier Transform in Linear Dynamics Procedures

Products Abaqus/Standard

Type History data

LevelStep

Optional parameters

METHOD

Set METHOD=CONSTANT to approximate the product of the response function and the complex exponent with a piecewise constant function for the inverse or direct Fourier transform calculation.

Set METHOD=DISCRETE to use the discrete Fourier transform.

Set METHOD=LINEAR to approximate the frequency response for the inverse Fourier transform calculation or the time domain response for the direct Fourier transform calculation with a piecewise linear function. This approximation is used to calculate the Fourier integral analytically.

SCALE

Set SCALE equal to the scale factor for the calculated direct or inverse Fourier transform. The default is SCALE=1.0.

There are no data lines associated with this option