Products
Abaqus/Standard
Abaqus/CAE
Type
History data
LevelStep
Abaqus/CAE
Load module
Optional parameters
-
AMPLITUDE
-
Set this parameter equal to the name of the amplitude curve that defines
the magnitude of the electric current density during the step (Amplitude Curves). If this parameter is omitted, the
reference magnitude is applied immediately at the beginning of the step
or linearly over the step, depending on the value assigned to the
AMPLITUDE parameter on
the STEP option
(Defining an Analysis).
-
OP
-
Set
OP=MOD
(default) for existing DSECURRENTs to
remain, with this option defining distributed current densities to be
added or modified.
Set
OP=NEW
if all existing DSECURRENTs
applied to the model should be removed.
Optional, mutually exclusive parameters for time-harmonic eddy current
analyses
-
IMAGINARY
-
Include this parameter to define the imaginary (out-of-phase) part of the
surface current density.
-
REAL
-
Include this parameter (default) to define the real (in-phase) part of
the surface current density.
Data lines to define distributed electrical current densities in coupled
thermal-electrical or coupled thermal-electrical-structural analyses or to define
distributed electrical current densities in the solid phase in coupled
thermal-electrochemical, coupled thermal-electrochemical-structural, or coupled
thermal-electrochemical-structural-pore pressure analyses
- First line
-
Surface name.
Distributed current density type label
CS or
CSNU.
Reference surface current density magnitude. (Units of
CL−2T−1.) For
nonuniform loads the magnitude must be defined in user
subroutine DECURRENT.
If given, the magnitude will be passed into the user
subroutine.
Table collection name (optional). Only applicable for
nonuniform distributed current densities defined in user
subroutine DECURRENT.
Repeat this data line as often as necessary to define
current densities for various surfaces.
Data lines to define distributed fluid electrical current densities in
coupled thermal-electrochemical, coupled thermal-electrochemical-structural, or
coupled thermal-electrochemical-structural-pore pressure analyses
- First line
-
Surface name.
Distributed current density type label
ECS.
Reference surface current density magnitude. (Units of
CL−2T−1.)
Repeat this data line as often as necessary to define
current densities for various surfaces.
Data lines to define surface current densities in eddy current or
magnetostatic analyses
- First line
-
Surface name.
Surface current density type label
CK (uniform) or
CKNU
(nonuniform).
Reference surface current density magnitude. (Units of
CL−1T−1.)
1-component of the surface current density vector
direction.
2-component of the surface current density vector
direction.
3-component of the surface current density vector
direction.
- For nonuniform loads the magnitude and direction must be
defined in user subroutine UDSECURRENT.
If given, the magnitude and direction will be passed into the user
subroutine.
Name of the orientation option (Orientations) that defines the local
coordinate system in which the surface current density vector is
specified.
Repeat this data line as often as necessary to define
surface current densities for various surfaces.