Products
Abaqus/Standard
Abaqus/Explicit
Abaqus/CAE
Type
History data
LevelStep
Abaqus/CAE
Load module
Optional parameters
-
AMPLITUDE
-
Set this parameter equal to the name of the amplitude curve that defines the
magnitude of the distributed fluxes during the step (Amplitude Curves).
If this parameter is omitted for uniform flux types in an Abaqus/Standard analysis, the reference magnitude is applied immediately at the beginning of the
step or linearly over the step, depending on the value assigned to the
AMPLITUDE parameter on the STEP option (Defining an Analysis). If this
parameter is omitted in an Abaqus/Explicit analysis, the reference magnitude is applied immediately at the beginning of the
step.
In Abaqus/Standard for nonuniform distributed fluxes of type
BFNU and
SnNU the flux
magnitude is defined in user subroutine DFLUX and
AMPLITUDE references are ignored. In
Abaqus/Explicit for nonuniform distributed fluxes of type
BFNU and
SnNU the flux
magnitude is defined in user subroutine VDFLUX and
AMPLITUDE references are passed in
the user subroutine.
In Abaqus/Standard for nonuniform concentrated fluxes of type
MBFNU the flux magnitude is defined in user
subroutine UMDFLUX and
AMPLITUDE references are passed in
the user subroutine.
-
OP
-
Set
OP=MOD
(default) for existing DFLUXs to remain, with this
option modifying existing fluxes or defining additional fluxes.
Set
OP=NEW
if all existing DFLUXs applied to the model
should be removed.
Data lines to define a distributed heat flux or mass flux
- First line
-
Element number or element set label.
Distributed flux type label (see About the Element Library).
Reference flux magnitude. This value is needed for uniform fluxes only.
If this value is given for nonuniform fluxes, it will be passed into user
subroutine DFLUX in Abaqus/Standard, or VDFLUX in Abaqus/Explicit, where the actual flux magnitude is defined.
In heat transfer analysis,
the units are JT−1L−2 for surface fluxes and
JT−1L−3 for body fluxes. In mass
diffusion analysis, the units are PLT−1 for surface
fluxes and PT−1 for body fluxes.
Repeat this data line as often as necessary to define distributed
fluxes for different element surfaces.
Data lines to define a distributed ion flux
- First line
-
Element number or element set label.
Distributed flux type label BFCE
(see About the Element Library).
Reference flux magnitude. The units for ion concentration body flux are
mol L−3 T−1
Repeat this data line as often as necessary to define distributed
fluxes for different element surfaces.
Data lines to define a nonuniform distributed heat flux or mass flux in user
subroutine UMDFLUX
- First line
-
- Element set label.
- Distributed flux type label (see About the Element Library).
- Leave this entry blank (any value entered here is ignored).
- Table collection name or blank if no table collection is used.
Repeat this data line as often as necessary to define distributed
fluxes for different element surfaces.