Products
Abaqus/Standard
Abaqus/CAE
Type
History data
LevelStep
Required parameters
-
MAIN
-
Set this parameter equal to the name of the main surface of the contact pair used in
the crack propagation analysis.
-
SECONDARY
-
Set this parameter equal to the name of the secondary surface of the contact pair
used in the crack propagation analysis.
-
INTERACTION
-
Set this parameter equal to the name of the surface interaction property definition
that includes the specification of the fracture criterion.
Optional parameters
-
DEBONDING FORCE
-
This parameter is relevant only when
TYPE=VCCT,
TYPE=ENHANCED VCCT,
TYPE=PRX-VCCT,
or
TYPE=FATIGUE
is used on the FRACTURE CRITERION option.
Set
DEBONDING FORCE=STEP
(default) if the traction between the two surfaces at the crack tip is to be released
immediately during the following increment after debonding.
Set
DEBONDING FORCE=RAMP
if the traction between the two surfaces at the crack tip is to be released gradually
during succeeding increments after debonding to avoid a sudden loss of stability.
-
FREQUENCY
-
Set this parameter equal to the output frequency, in increments. The crack-tip
location and associated quantities will always be printed at the last increment of
each step unless FREQUENCY=0. The
default is FREQUENCY=1. Set
FREQUENCY=0 to suppress this output.
-
OUTPUT
-
If this parameter is omitted, crack propagation information will be printed in the
data (.dat) file but not stored in the results
(.fil) file.
Set
OUTPUT=FILE
to store the crack propagation information in the results file.
Set
OUTPUT=BOTH
to print the crack propagation information in the data file and to store it in the
results file.
-
TIME INCREMENT
-
Set this parameter equal to the suggested time increment for automatic time
incrementation to use for the first increment just after debonding starts. The default
is the last relative time given on the data lines below.
For fixed time incrementation the value of this parameter will be used as the time
increment after debonding starts if Abaqus/Standard finds it needs a smaller time increment than its current value. The time increment
size will be modified as required until debonding is complete.
Data lines to define the debonding amplitude curve
- First line
-
Time relative to the time at the start of debonding.
Relative amplitude of the stresses at the contact interface due to
bonding remaining at this time.
Etc., up to four time/amplitude pairs per line.
Repeat this data line as often as necessary to define the debonding
amplitude curve.