From the main menu bar, select .
-
In the Create Interaction dialog box that appears, do the
following:
-
Name the interaction.
For more information about naming objects, see Using basic dialog box components.
-
Select the step. You can define radiation from a surface only during a
heat transfer, coupled temperature-displacement, coupled
thermal-electrical, coupled thermal-electrochemical, coupled
thermal-electrochemical structure, or coupled thermal-electrochemical
structure pore pressure step.
-
Select the Surface radiation type of interaction.
-
Click Continue to close the Create
Interaction dialog box.
-
Use one of the following methods to select the surface:
You can use the angle method to select a group of faces or edges from geometry
or a group of element faces from a mesh. For more information, see Using the angle and feature edge method to select multiple objects.
-
In the Edit Interaction dialog box that appears, select
the Radiation type.
-
Select To ambient to specify heat transfer to the
surrounding environment.
-
Select Cavity approximation (3D only) to
approximate cavity radiation in three-dimensional models using uniform
emissivity, a closed cavity, and an average cavity temperature.
-
If you selected To ambient in the previous step, complete
the radiation definition as follows:
-
Click the arrow to the right of the Emissivity
distribution field, and select the option of your choice
from the list that appears:
-
Select Uniform to define an emissivity
that is uniform over the surface.
-
Select an analytical field to define a spatially varying
emissivity. Only analytical fields that are valid for this
interaction type are displayed in the selection list.
Alternatively, you can click
to
create a new analytical field. (See The Analytical Field toolset for more information.)
-
In the Emissivity field, enter the emissivity of
the surface,
.
-
In the Ambient temperature field, enter the
ambient temperature,
.
-
If you want to vary the ambient temperature with time, click the arrow
to the right of the Ambient temperature amplitude
field and select an amplitude from the list that appears. If desired,
click
to create a new
amplitude; see Selecting an amplitude type to define for more
information.
-
If you selected Cavity approximation (3D only) in Step 5,
enter the emissivity of the surface,
, in the Emissivity field.
-
Specify the absolute zero temperature,
, on the temperature scale being used and the Stefan-Boltzmann
constant,
, in the Edit Model Attributes dialog box,
as described in Specifying model attributes.
-
Check the Toggle on dynamic surface activation check box
to specify the radiation condition on the evolving faces of an element.
-
Click OK to create the interaction and to close the