Specifying Design Responses in a Transient Dynamic Analysis
A transient dynamic adjoint design sensitivity analysis supports two kinds of
design responses: node responses and element responses. The node responses refer to
quantities such as displacements or reaction forces and moments at one or more nodes in
the structure.
You request design responses using a syntax analogous to that for specifying output
requests to the output database. There are no default responses. If no responses are
requested, no design responses and no sensitivities are output. Specifying a response
outputs both the design response value and its sensitivities. You must specify a node
set or an element set as part of a node or an element design response definition. If the
set contains more than one entity (node or element), the design response contains the
sum of the contributions from all of the entities in the set.
Optionally, you can specify one or more time points at which a physical quantity of
interest is to be treated as a design response. If no time point is specified, the time
point corresponding to the end of the step is used for the design response.
Input File Usage
Use the following options to request element design responses at a specific time
point:
Use the following options to request node design responses at a specific time
point:
DESIGN RESPONSE, NAME=response name, TIME MARKS=YES, TIME POINTS=time point nameNODE RESPONSE, NSET=nset name, ORIENTATION=orientation name
Each design response specification block must request only a single design
response. Multiple design responses require multiple uses of the design response
specification block, once for each response.
Defining the Design Response in User Subroutine
UELEMDRESP