This parameter is meaningful only in an adjoint design sensitivity analysis.
For the stress (MISES,
S_MISES,
SP3,
SP1), principal strain
(EP3,
EP1), principal logarithmic strain
(LEP3,
LEP1), principal nominal strain
(NEP3,
NEP1), Neuber equivalent stress
(NBSEQ), Glinka equivalent stress
(GKSEQ), Neuber equivalent strain
(NBEEQ), Glinka equivalent strain
(GKEEQ), Neuber equivalent plastic
strain (NBPEEQ), Glinka equivalent
plastic strain (GKPEEQ), plastic
strain magnitude (PEMAG), or
user-defined element responses, set this parameter equal to the method used for
calculating the values of the responses and the approximated sensitivities based on
the values of these quantities at the element integration points of the element
set.
For the internal force
(INTFn
and INTFMAG) element responses, set this parameter
equal to the method for calculating the values of the responses and the corresponding
sensitivities based on the values of these quantities in the specified element
set.
Set
OPERATOR=MAX
(default for MISES,
S_MISES, SP3,
SP1, EP3,
EP1, LEP3,
LEP1, NEP3,
NEP1,
PEMAG,
NBSEQ, GKSEQ,
NBEEQ, GKEEQ,
NBPEEQ, GKPEEQ,
and user-defined responses) to indicate that the calculation method for the design
response represents the maximum value of the element set.
Set
OPERATOR=MAXABS
to indicate that the calculation method for the design response represents the maximum
absolute value of the element set. This parameter is not available for design
responses in a steady-state dynamic analysis.
Set
OPERATOR=MINABS
to indicate that the calculation method for the design response represents the minimum
absolute value of the element set. This parameter is not available for design
responses in a steady-state dynamic analysis.
Set
OPERATOR=MIN
to indicate that the calculation method for the design response represents the minimum
value for the element set.
Set
OPERATOR=SUB
to indicate that the calculation method for the design response represents the
difference between the maximum and the minimum values for the element set.
Set
OPERATOR=AVE
to indicate that the calculation method for the design response represents the average
value for the element set.
Set
OPERATOR=SUM
(default for
INTFn
and INTFMAG) to indicate that the calculation method
for the design response represents the sum over the element set.