UECHEMECDLPL

User subroutine to define the lithium plating (LPL) aging current to be used for elements that utilize porous electrode theory in an electrochemical analysis.

User subroutine UECHEMECDLPL:

  • is called for each material integration point for each iteration;
  • is called for each microscale particle that is defined at the active electrodes during an electrochemical analysis;
  • can be used to define the LPL current to model aging in batteries (see Lithium Plating); and
  • can be used only in procedures that support electrochemical analyses (see Electrochemical Analysis).