The types of electromagnetic loads available depend on the analysis
being performed, as described in the sections below. See About Loads for general information that applies to all types of loading.
The prescribed magnitude of a concentrated or a distributed
electromagnetic load can vary with time during a step according to an amplitude definition,
as described in About Prescribed Conditions. If
different variations are needed for different loads, each load can refer to its own
amplitude definition.
In a time-harmonic eddy current analysis all loads are assumed to
be time-harmonic.
Modifying Electromagnetic Loads
Concentrated or distributed electromagnetic loads can be added,
modified, or removed as described in About Loads.
Prescribing Electromagnetic Loads for Piezoelectric
Analyses
In a piezoelectric analysis a concentrated electric charge can be
prescribed at nodes, a distributed electric surface charge can be defined on element faces
and surfaces, and a distributed electric body charge can be defined on elements.
Specifying Concentrated Electric Charge
To specify a concentrated electric charge, specify the node or
node set and the magnitude of the charge.
Input File Usage
CECHARGEnode number or node set name, , charge magnitude
Abaqus/CAE Usage
Load module: Create Load: choose Electrical/Magnetic for the Category and Concentrated charge for the Types for Selected Step; Magnitude: charge magnitude
Specifying Element-Based Distributed Electric
Charge
You can specify a distributed surface charge (on element faces)
or a distributed body charge (charge per unit volume). For an element-based surface charge
you must identify the face of the element upon which the charge is prescribed in the
charge label. The distributed charge types available depend on the element type. About the Element Library lists the
distributed charges that are available for particular elements.
Input File Usage
DECHARGEelement number or element set name, charge label, charge magnitude
where charge label is ESn or EBF
Abaqus/CAE Usage
Use the following input to define a distributed
surface charge on element faces:
Load module: Create Load: choose Electrical/Magnetic for the Category and Surface charge for the Types for Selected Step; Distribution: select an analytical field, Magnitude: charge magnitude
Use the following input to define a body
charge:
Load module: Create Load: choose Electrical/Magnetic for the Category and Body charge for the Types for Selected Step
Specifying Surface-Based Distributed Electric
Charge
When you specify a distributed electric charge on a surface, the
element-based surface (see Element-Based Surface Definition) contains the
element and face information. You must specify the surface name, the electric charge
label, and the electric charge magnitude.
Load module: Create Load: choose Electrical/Magnetic for the Category and Surface charge for the Types for Selected Step; Distribution: Uniform, Magnitude: charge magnitude
Specifying Electric Charge in Direct-Solution Steady-State
Dynamics Analysis
In the direct-solution steady-state dynamics procedure, electric
charges are given in terms of their real and imaginary components.
Input File Usage
Use the following options to define electric
charges in direct-integration steady-state dynamics analysis:
CECHARGE, REAL or IMAGINARY (real or imaginary component)DECHARGE, REAL or IMAGINARYDSECHARGE, REAL or IMAGINARY
Abaqus/CAE Usage
Load module: Create Load: choose Electrical/Magnetic for the Category and Concentrated charge, Surface charge, or Body charge for the Types for Selected Step; Magnitude: real component + imaginary component
Loading in Mode-Based and Subspace-Based Procedures
Electrical charge loads should be used only in conjunction with
residual modes in the eigenvalue extraction step, due to the “massless” mode effect. Since
the electrical potential degrees of freedom do not have any associated mass, these degrees
of freedom are essentially eliminated (similar to Guyan reduction or mass condensation)
during the eigenvalue extraction. The residual modes represent the static response
corresponding to the electrical charge loads, which will adequately represent the
potential degree of freedom in the eigenspace.
Prescribing Electromagnetic Loads for Coupled
Thermal-Electrical and Fully Coupled Thermal-Electrical-Structural Analyses
In a coupled thermal-electrical analysis and fully coupled
thermal-electrical-structural analysis a concentrated current can be prescribed at nodes,
distributed current densities can be defined on element faces and surfaces, and distributed
body currents can be defined on elements.
Specifying Concentrated Current Density
To define concentrated currents, specify the node or node set and
the magnitude of the current.
Input File Usage
CECURRENTnode number or node set name, , current magnitude
Abaqus/CAE Usage
Load module: Create Load: choose Electrical/Magnetic for the Category and Concentrated current for the Types for Selected Step; Magnitude: current magnitude
Specifying Element-Based Distributed Current
Density
You can specify distributed surface current densities (on element
faces) or distributed body current densities (current per unit volume). For element-based
surface current densities you must identify the face of the element upon which the current
is prescribed in the current label. The distributed current types available depend on the
element type. About the Element Library lists the
distributed current densities that are available for particular elements.
Input File Usage
DECURRENTelement number or element set name, current density label, current density magnitude
where the current density label is CSn, CS1, CS2, or CBF
Abaqus/CAE Usage
Use the following input to define a distributed
surface current density on element faces:
Load module: Create Load: choose Electrical/Magnetic for the Category and Surface current for the Types for Selected Step; Distribution: select an analytical field, Magnitude: current density magnitude
Use the following input to define a body current
density:
Load module: Create Load: choose Electrical/Magnetic for the Category and Body current for the Types for Selected Step
Specifying Surface-Based Distributed Current
Densities
When you specify distributed current densities on a surface, the
element-based surface (see Element-Based Surface Definition) contains the
element and face information. You must specify the surface name, the current density
label, and the current density magnitude.
Input File Usage
DSECURRENTsurface name, CS, current density magnitude
Abaqus/CAE Usage
Load module: Create Load: choose Electrical/Magnetic for the Category and Surface current for the Types for Selected Step: Distribution: Uniform, Magnitude: current density magnitude
Defining Nonuniform Current Density Magnitude in a User
Subroutine
Nonuniform element volume, element facet, and nonuniform surface
current density magnitude can be defined with user subroutine DECURRENT.
If the magnitude is given, the value is passed into the user subroutine.
Input File Usage
Use the following option to define nonuniform
element-based current density magnitude:
DECURRENTelement number or element set name, current density label,current density magnitude, table collection name
where the current density label is CSnNU ( CS1NU, CS2NU, CS3NU, CS4NU, CS5NU, CS6NU),or CBFNU.
Use the following option to define nonuniform
surface-based current density magnitude:
DSECURRENTsurface name, CSNU, current density magnitude, table collection name
Abaqus/CAE Usage
Use the following option to define nonuniform
volume current density:
Load module: Create Load: choose Electrical/Magnetic for the Category and Body current density for the Types for Selected Step; Distribution: User-defined
Use the following option to define nonuniform
surface current density:
Load module: Create Load: choose Electrical/Magnetic for the Category and Surface current density for the Types for Selected Step; Distribution: User-defined
Prescribing Electromagnetic Loads for Eddy Current and/or
Magnetostatic Analyses
In an eddy current analysis a distributed surface current density
vector can be defined on surfaces and a distributed volume current density vector can be
defined on elements.
Specifying Element-Based Distributed Current Density
Vectors
When you define a distributed volume current density vector, you
must specify the element or element set, the current density vector label, the magnitude
of the current density vector, the vector components of the current density, and an
optional orientation name that defines the local coordinate system in which the vector
components are specified. By default, the vector components of the current density are
defined with respect to the global directions.
The specified current density vector direction components are
normalized by Abaqus and, thus, do not contribute to the magnitude of the load.
Input File Usage
DECURRENTelement number or element set name, CJ, current density vector magnitude, current density vector direction components, orientation name
Abaqus/CAE Usage
Load module: Create Load: choose Electrical/Magnetic for the Category and Body current density for the Types for Selected Step; Distribution: Uniform
Specifying Surface-Based Distributed Current Density
Vectors
When you specify distributed current density vectors on a
surface, the element-based surface (see Element-Based Surface Definition) contains the
element and face information. You must specify the surface name, the current density
vector label, and the magnitude of the current density vector, the vector components of
the current density, and an optional orientation name that defines the local coordinate
system in which the surface current density is specified. By default, the vector
components of the current density are defined with respect to the global directions.
The specified current density vector direction components are
normalized by Abaqus and, thus, do not contribute to the magnitude of the load.
Input File Usage
DSECURRENTsurface name, CK, current density vector magnitude, current density vector direction components, orientation name
Abaqus/CAE Usage
Load module: Create Load: choose Electrical/Magnetic for the Category and Surface current density for the Types for Selected Step; Distribution: Uniform
Defining Nonuniform Current Density Vectors in a User
Subroutine
Nonuniform volume current density vectors can be defined with
user subroutine UDECURRENT,
and nonuniform surface current density vectors can be defined with user subroutine UDSECURRENT.
If the magnitude and direction components are given, the values are passed into the user
subroutine.
Input File Usage
Use the following option to define nonuniform
element-based current density vectors:
DECURRENTelement number or element set name, CJNU, current density vector magnitude, current density vector direction components, orientation name
Use the following option to define nonuniform
surface-based current density vectors:
DSECURRENTsurface name, CKNU, current density vector magnitude, current density vector direction components, orientation name
Abaqus/CAE Usage
Use the following option to define nonuniform
volume current density:
Load module: Create Load: choose Electrical/Magnetic for the Category and Body current density for the Types for Selected Step; Distribution: User-defined
Use the following option to define nonuniform
surface current density:
Load module: Create Load: choose Electrical/Magnetic for the Category and Surface current density for the Types for Selected Step; Distribution: User-defined
Specifying Real and Imaginary Components of Current Density
Vectors in a Time-Harmonic Eddy Current Analysis
In a time-harmonic eddy current analysis, current density vectors
are given in terms of their real (in-phase) and imaginary (out-of-phase) components.
Input File Usage
Use the following options to define current
density vectors:
Load module: Create Load: choose Electrical/Magnetic for the Category and Body current density or Surface current density for the Types for Selected Step; real components + imaginary components