This option is used to identify a submodel cut where the submodel conditions will be
imposed and to specify the submodel control settings specific to a submodel cut. It must
be used as a suboption of the SUBMODEL CONDITIONS
option.
Set this parameter equal to the name of the element-based surface
where the submodel conditions are being imposed.
Optional parameters
ABSOLUTE EXTERIOR TOLERANCE
Set this parameter equal to the absolute value (given in the units used
in the model) by which a driven node of the submodel can lie outside the
region of the elements of the global model.
If this parameter is omitted or has a value of 0.0, the
EXTERIOR TOLERANCE
applies.
EXTERIOR TOLERANCE
Set this parameter equal to the fraction of the average element size in
the global model by which a driven node can lie outside the region of
the elements of the global model.
The default is 0.05.
GLOBAL ELSET
Set this parameter equal to the name of the element set in the global
model that will be searched for elements whose responses are being used
to impose the submodel conditions.
If this parameter is omitted, Abaqus/Standard searches all the elements in the global model.
MAIN IMPOSED CONDITIONS
Set
MAIN IMPOSED CONDITIONS=PRIMARY
(default) to impose conditions on the primary degrees of freedom.
Set
MAIN IMPOSED CONDITIONS=NONE
to impose no conditions on the primary degrees of freedom.
OP
Set OP =
MOD (default) to
modify the imposed conditions on this submodel cut surface.
Set OP =
NEW to remove the
previously imposed conditions on this submodel cut surface and to apply
the newly specified conditions.
Data line to define the degrees of freedom for imposed boundary
conditions
First line
The degree of freedom to be imposed
or exempted.
Specify NONE if this
degree of freedom should not be imposed; specify
PRIMARY if this degree of
freedom should be imposed.