Products
Abaqus/Standard
Type
History data
LevelStep
Required parameters
-
NAME
-
Set this parameter equal to the name associated with this sensor-based
step control definition. The sensor’s name itself is given on the data
line.
Optional parameters
-
ACTION
-
By default, the step control definition is utilized for time increment
refinement when the value of the sensor is within a specified interval.
In this case, no threshold value of the sensor is necessary. The
nondefault actions of a step control definition require the
specification of a threshold value of the sensor.
Set
ACTION=CONTINUE
(default) to trigger time increment refinement when the value of the
sensor is within a specified interval. It must be used in conjunction
with
DT REFINEMENT=YES.
Set
ACTION=END ANALYSIS
to end the analysis completely when the sensor reaches a specified
threshold value.
Set
ACTION=END STEP
to conclude the current step and to continue to the next step when the
sensor reaches a specified threshold value.
-
DT REFINEMENT
-
You can specify two limits and control the time incrementation when the
sensor value is within the range defined by the two limits to get finer
resolution on the solution within a specified range of values for the
sensor while using normal time increments outside of this range.
Alternatively, you can specify a limit and a threshold value and control
the time incrementation when the sensor value is in that range.
Set
DT REFINEMENT=AUTO
to indicate that Abaqus/Standard should refine the time increment automatically to reach the threshold
as closely as possible.
Set
DT REFINEMENT=NO
to leave the time increment unaffected.
Set
DT REFINEMENT=YES
(default) to indicate that a user-specified fixed time increment should
be used.
-
TOLERANCE
-
Set this parameter equal to the tolerance to be used to determine when
the sensor has reached the threshold value. The
TOLERANCE parameter
must be used in conjunction with
DT REFINEMENT=AUTO.
Abaqus/Standard enforces the relative error in the sensor value with respect to its
threshold value to be less than the specified tolerance. The default
value of the tolerance is 0.001.
Data lines to define a sensor-based step control to end the current step
or the analysis without refining the time incrementation
(DT REFINEMENT=NO,
ACTION=END STEP
or
ACTION=END ANALYSIS)
- First data line
-
Sensor name.
Threshold criteria (Max, Min, AbsMax, or
AbsMin).
Sensor threshold value.
Repeat this data line as often as necessary to define
different stopping criteria, potentially using different
sensors.
Data lines to define a sensor-based step control to end the current step
or the analysis with automatic refinement of the time incrementation
(DT REFINEMENT=AUTO,
ACTION=END STEP
or
ACTION=END ANALYSIS)
- First data line
-
Sensor name.
Threshold criteria (Max, Min, AbsMax, or
AbsMin).
Sensor threshold value.
Repeat this data line as often as necessary to define
different stopping criteria, potentially using different
sensors.
Data lines to define a sensor-based step control to end the current step
or the analysis with a user-specified refinement of the time incrementation
(DT REFINEMENT=YES,
ACTION=END STEP
or
ACTION=END ANALYSIS)
- First data line
-
Sensor name.
Threshold criteria (Max, Min, AbsMax, or
AbsMin).
Sensor threshold value.
Time increment value to be used, provided that it is lower
than the time increment computed by the automatic
time-incrementation algorithms in Abaqus/Standard and the condition for time increment refinement is
met.
- Sensor limit value when the time increment refinement
starts.
- Blank.
Repeat this data line as often as necessary to define
different stopping criteria, potentially using different
sensors.
Data lines to define a sensor-based step control, with a user-specified
refinement of the time incrementation, to get a finer resolution of the solution
within a specified interval
(DT REFINEMENT=YES,
ACTION=CONTINUE)
- First data line
-
Sensor name.
Blank.
Blank.
Time increment value to be used, provided that it is lower
than the time increment computed by the automatic
time-incrementation algorithms in Abaqus/Standard and the condition for time increment refinement is
met.
- Sensor limit value when the time increment refinement
starts.
- Sensor limit value when the time increment refinement
ends.
Repeat this data line as often as necessary to refine
the time increment in regions of interest, potentially using different
sensors.
|