Products
Abaqus/Standard
Abaqus/Explicit
Abaqus/CAE
Type
History data
LevelStep
Abaqus/CAE
Interaction module
Optional parameters
-
FILM AMPLITUDE
-
This parameter applies only to Abaqus/Standard and Abaqus/Explicit analyses.
Set this parameter equal to the name of the AMPLITUDE option that gives the
variation of the film coefficient, h, with time.
If this parameter is omitted in an Abaqus/Standard analysis, the reference film coefficient is applied immediately at the beginning of
the step and kept constant over the step, independent of the value assigned to the
AMPLITUDE parameter on the STEP option. If this parameter
is omitted in an Abaqus/Explicit analysis, the reference sink temperature given on the data lines is applied
throughout the step.
The FILM AMPLITUDE parameter is
ignored if a film coefficient is defined to be a function of temperature and field
variables using the FILM PROPERTY option.
For nonuniform films of type FNU, the film
coefficient amplitude is defined in user subroutine FILM in Abaqus/Standard or user subroutine VFILM in Abaqus/Explicit; and FILM AMPLITUDE references
are used only to modify the film coefficient passed into the user subroutine.
-
OP
-
Set
OP=MOD
(default) to modify existing films or to define additional films.
Set
OP=NEW
if all existing SFILMs applied to the model
should be removed.
-
SINK AMPLITUDE
-
Set this parameter equal to the name of the AMPLITUDE option that gives the
variation of the sink temperature,
, with time.
If this parameter is omitted in an Abaqus/Standard analysis, the reference sink temperature is applied immediately at the beginning of
the step or linearly over the step, depending on the value assigned to the
AMPLITUDE parameter on the STEP option (Defining an Analysis). If this
parameter is omitted in an Abaqus/Explicit analysis, the reference sink temperature is applied immediately at the beginning of
the step.
For nonuniform films of type FNU, the sink
temperature amplitude is defined in user subroutine FILM in Abaqus/Standard or user subroutine VFILM in Abaqus/Explicit; and SINK AMPLITUDE references
are used only to modify the sink temperature passed into the user subroutine.
Data lines to define sink temperatures and film coefficients
- First line
-
Surface name.
Film type label F or
FNU.
Reference sink temperature value,
. (Units of
.) For nonuniform film coefficients the sink temperature
must be defined in user subroutine FILM in Abaqus/Standard or user subroutine VFILM in Abaqus/Explicit. If given, this value will be modified by the
SINK AMPLITUDE reference and
passed into the user subroutine.
Reference film coefficient value, h (units of
JT−1L−2
−1), or name of the film property table defined
with the FILM PROPERTY option.
Nonuniform film coefficients must be defined in user subroutine FILM in Abaqus/Standard or user subroutine VFILM in Abaqus/Explicit. If given, this value will be modified by the
FILM AMPLITUDE reference and
passed into the user subroutine.
Repeat this data line as often as necessary to define film conditions
for different surfaces.