Products
Abaqus/Standard
Abaqus/Explicit
Abaqus/CAE
Type
History data
LevelStep
Abaqus/CAE
Interaction module
Optional parameters
-
AMBIENT AMPLITUDE
-
Set this parameter equal to the name of the AMPLITUDE option
that gives the variation of the ambient temperature with time.
If this parameter is omitted in an Abaqus/Standard analysis, the reference magnitude is applied immediately at the
beginning of the step or linearly over the step, depending on the value
assigned to the
AMPLITUDE parameter on
the STEP option (see
Defining an Analysis). If this parameter is omitted in an Abaqus/Explicit analysis, the reference magnitude given on the data lines is applied
throughout the step.
-
OP
-
Set
OP=MOD
(default) for existing RADIATE
definitions to remain, with this option modifying existing radiation
conditions or defining additional radiation conditions.
Set
OP=NEW
if all existing RADIATE
definitions applied to the model should be removed.
-
RADIATION AMPLITUDE
-
Set this parameter equal to the name of the AMPLITUDE option
that gives the variation of the total radiation flux with time.
If this parameter is omitted in an Abaqus/Standard analysis, the total radiation flux, accounting for any
AMBIENT AMPLITUDE, is
applied immediately, independent of the value assigned to the
AMPLITUDE parameter on
the STEP option. If
this parameter is omitted in an Abaqus/Explicit analysis, the total radiation flux, accounting for any
AMBIENT AMPLITUDE, is
applied immediately at the beginning of the step.
-
REGION TYPE
-
This parameter applies only to Abaqus/Explicit analyses.
This parameter is relevant only for radiation conditions applied to the
boundary of an adaptive mesh domain. If a radiation condition is applied
to a surface in the interior of an adaptive mesh domain, the nodes on
the surface will move with the material in all directions (they will be
nonadaptive). Abaqus/Explicit will create a boundary region automatically on the surface subjected
to the defined radiation condition.
Set
REGION TYPE=LAGRANGIAN
(default) to apply the radiation condition to a Lagrangian boundary
region. The edge of a Lagrangian boundary region will follow the
material while allowing adaptive meshing along the edge and within the
interior of the region.
Set
REGION TYPE=SLIDING
to apply the radiation condition to a sliding boundary region. The edge
of a sliding boundary region will slide over the material. Adaptive
meshing will occur along the edge and in the interior of the region.
Mesh constraints are typically applied on the edge of a sliding boundary
region to fix it spatially.
Set
REGION TYPE=EULERIAN
to apply the radiation condition to an Eulerian boundary region. This
option is used to create a boundary region across which material can
flow. Mesh constraints must be used normal to an Eulerian boundary
region to allow material to flow through the region. If no mesh
constraints are applied, an Eulerian boundary region will behave in the
same way as a sliding boundary region.
Data lines to define radiation conditions
- First line
-
Element number or element set name.
Radiation type (see About the Element Library).
Reference ambient temperature value,
. (Units of
.)
Emissivity,
.
Repeat this data line as often as necessary to define
radiation conditions.