Define contact initialization methods for general contact.
This option is used to define contact initialization methods. The contact initialization
method is applied to a contact interaction using the CONTACT INITIALIZATION ASSIGNMENT
option.
Set this parameter equal to a label that is used to refer to this contact
initialization method.
Optional, mutually exclusive parameters
INITIAL CLEARANCE
Set this parameter equal to a positive value to specify an initial clearance
distance.
In Abaqus/Standard set this parameter equal to the name of a CLEARANCE option to specify an
initial clearance distance. The named clearance definition can be used for general
contact interactions in portions of the model where the small-sliding tracking
approach is active, for general contact interactions that use the finite-sliding
tracking approach, or for interactions in procedures that have no mechanical degrees
of freedom, such as heat transfer, coupled thermal-electrical, or coupled
thermal-electrochemical.
INTERFERENCE FIT
Include this parameter without setting it to a value to treat initial overclosures as
interference fits.
Set this parameter equal to a positive value to specify an interference distance.
If this parameter is omitted, initial overclosures are resolved with strain-free
adjustments.
Optional parameters
ADJUST
Set
ADJUST=YES
(default) to resolve clearances/overclosures by adjusting the nodal coordinates
without creating strain in the model. In Abaqus/ExplicitADJUST=YES
can be used only for clearances/overclosures defined in the first step of an analysis.
In Abaqus/StandardADJUST=YES
can be used only for clearances/overclosures defined in model data (before the first
step).
Set
ADJUST=NO
to store contact offsets so that the clearances/overclosures can be satisfied without
adjusting the nodal coordinates. In Abaqus/Standard this setting can be used for general contact interactions in
portions of the model where the small-sliding tracking approach is active, for
interactions that are permanently bonded with cohesive contact, and for interactions
in heat transfer and coupled electrical-thermal procedures that have no mechanical
degrees of freedom. The setting is ignored when the
INTERFERENCE FIT parameter or the
INITIAL CLEARANCE parameter with a
value is specified.
MINIMUM DISTANCE
This parameter applies only to Abaqus/Standard analyses.
Set
MINIMUM DISTANCE=YES
(default) to automatically activate localized contact damping when nearby surfaces are
touching at only a single point.
Set
MINIMUM DISTANCE=NO
to forgo this automatic localized damping.
SEARCH ABOVE
Set this parameter equal to a positive value to ensure that the search zone for
contact initialization includes gaps at least as large as the specified value.
SEARCH BELOW
Set this parameter equal to a positive value to ensure that the search zone for
contact initialization includes overclosures at least as large as the specified value.
SEARCH NSET
This parameter applies only to Abaqus/Explicit analyses using the
INITIAL CLEARANCE parameter. It
cannot be used if either the
SEARCH ABOVE or
SEARCH BELOW parameter is used.
Set this parameter equal to the name of the node set containing the secondary nodes
to be included in the initial clearance specification. The specified clearance is
enforced at all secondary nodes in this node set irrespective of whether they are
above or below their respective main surfaces. This parameter can also be used to
identify initially bonded nodes in a VCCT analysis.
STEP FRACTION
This parameter applies only to Abaqus/Explicit analyses using the
INTERFERENCE FIT parameter.
Fraction of the step time (between 0.0 and 1.0) in which the interference fit has to
be solved. The default value is 1.0.
There are no data lines associated with this option.