ProductsAbaqus/StandardAbaqus/CAE
TypeHistory data
LevelStep
Abaqus/CAEStep module
Optional parameters
- CONSTRAINT OPTIMIZATION
-
Include this parameter to optimize the handling of hard contact and
compressibility constraints associated with hybrid elements.
- RESET
-
Include this parameter to reset all of the iterative solver controls to
their default values. The option should have no data lines when this parameter
is used.
If this parameter is omitted, only the iterative solver specified controls
will be changed in the current step; the other controls will remain at their
settings from previous steps.
Data line to
define control parameters for the iterative solver
- First (and only) line
-
-
Relative tolerance for convergence. The default is 10−6 for all
linear perturbation and general nonlinear procedures.
-
Maximum number of iterations allowed. The default is 500.
-
ILU factorization fill-in level. The
default is 0; the maximum is 3. This parameter applies only to porous media
(soils) analyses.