ProductsAbaqus/StandardAbaqus/ExplicitAbaqus/CAE
TypeHistory data
LevelStep
Abaqus/CAEInteraction module
Optional parameters
- AMPLITUDE
-
Set this parameter equal to the name of the
AMPLITUDE option that gives the variation of the sink temperature,
,
with time.
If this parameter is omitted in an
Abaqus/Standard
analysis, the reference sink temperature is applied immediately at the
beginning of the step or linearly over the step, depending on the value
assigned to the AMPLITUDE parameter on the
STEP option (Defining an Analysis).
If this parameter is omitted in an
Abaqus/Explicit
analysis, the reference sink temperature is applied immediately at the
beginning of the step.
For nonuniform films of type FNU, the sink temperature
amplitude is defined in user subroutine FILM in Abaqus/Standard or user subroutine VFILM in Abaqus/Explicit; and AMPLITUDE references are
used only to modify the sink temperature passed into the user subroutine.
- FILM AMPLITUDE
-
This parameter applies only to
Abaqus/Standard
and
Abaqus/Explicit
analyses.
Set this parameter equal to the name of the
AMPLITUDE option that gives the variation of the film coefficient,
h, with time.
If this parameter is omitted in an
Abaqus/Standard
analysis, the reference film coefficient is applied immediately at the
beginning of the step and kept constant over the step, independent of the value
assigned to the AMPLITUDE parameter on the
STEP option. If this parameter is omitted in an
Abaqus/Explicit
analysis, the reference sink temperature given on the data lines is applied
throughout the step.
The FILM AMPLITUDE parameter is ignored if a film coefficient is defined to be a
function of temperature and field variables using the
FILM PROPERTY option.
For nonuniform films of type FNU, the film coefficient
amplitude is defined in user subroutine FILM in Abaqus/Standard or user subroutine VFILM in Abaqus/Explicit; and FILM AMPLITUDE references
are used only to modify the film coefficient passed into the user subroutine.
- OP
-
Set OP=MOD (default) to modify existing films or to define additional
films.
Set OP=NEW if all existing
SFILMs applied to the model should be removed.
Data lines to define
sink temperatures and film coefficients
- First line
-
Surface name.
-
Film type label F or FNU.
-
Reference sink temperature value,
. (Units of
.) For nonuniform film coefficients the sink temperature
must be defined in user subroutine FILM in Abaqus/Standard or user subroutine VFILM in Abaqus/Explicit. If given, this value will be modified by the
AMPLITUDE reference and passed
into the user subroutine.
-
Reference film coefficient value, h (units of
JT−1L−2
−1), or name of the film property table
defined with the FILM PROPERTY option.
Nonuniform film coefficients must be defined in user subroutine FILM in Abaqus/Standard or user subroutine VFILM in Abaqus/Explicit. If given, this value will be modified by the
FILM AMPLITUDE reference and
passed into the user subroutine.
Repeat this data line as
often as necessary to define film conditions for different
surfaces.