Defining the loading response data for uniaxial behavior in connectors
Optional parameters
- DEPENDENCIES
-
Set this parameter equal to the number of field variable dependencies included in the definition of the data, in addition to temperature. If this parameter is omitted, it is assumed that the data depend only on temperature. The DEPENDENCIES parameter also applies to any subsequent unloading data defined using the UNLOADING DATA option.
- DIRECTION
-
Set DIRECTION=TENSION to define tensile behavior.
Set DIRECTION=COMPRESSION to define compressive behavior.
If this parameter is omitted, the behavior is assumed to be nonlinear elastic and the data may span both positive and negative values of the primary component. The behavior will be considered to be symmetric about the origin if the given data are limited to either positive or negative values of the primary component.
- EXTRAPOLATION
-
Set EXTRAPOLATION=CONSTANT to use constant extrapolation of the dependent variables outside the specified range of the independent variables.
Set EXTRAPOLATION=LINEAR to use linear extrapolation of the dependent variables outside the specified range of the independent variables.
The default is EXTRAPOLATION=CONSTANT unless CONNECTOR BEHAVIOR, EXTRAPOLATION=LINEAR is used. The EXTRAPOLATION parameter also applies to any subsequent unloading data defined using the UNLOADING DATA option.
- INDEPENDENT COMPONENTS
-
Set INDEPENDENT COMPONENTS=CONSTITUTIVE MOTION to specify dependencies on components of constitutive relative motion included in the uniaxial behavior definition. The INDEPENDENT COMPONENTS parameter should not be used if uniaxial behavior is dependent on only the component of constitutive relative motion specified with the COMPONENT parameter on the CONNECTOR UNIAXIAL BEHAVIOR option. The INDEPENDENT COMPONENTS parameter also applies to any subsequent unloading data defined using the UNLOADING DATA option.
- REGULARIZE
-
Set REGULARIZE=ON to regularize the user-defined tabular loading data.
Set REGULARIZE=OFF to use the user-defined tabular loading data directly without regularization.
The default is REGULARIZE=ON unless CONNECTOR BEHAVIOR, REGULARIZE=OFF is used. The REGULARIZE parameter also applies to any subsequent unloading data defined using the UNLOADING DATA option.
- RTOL
-
Set this parameter equal to the tolerance to be used to regularize the user-defined tabular loading data. If this parameter is omitted, the default is RTOL=0.03 unless the tolerance is specified on the CONNECTOR BEHAVIOR option.
This parameter is ignored if REGULARIZE=OFF.
The RTOL parameter also applies to any subsequent unloading data defined using the UNLOADING DATA option.
- TYPE
-
Set TYPE=DAMAGE to define a damage elasticity model. TYPE=DAMAGE must be used in conjunction with the DIRECTION parameter.
Set TYPE=ELASTIC (default) to define a nonlinear elastic model with or without rate dependency.
Set TYPE=PERMANENT DEFORMATION to define models that exhibit permanent deformation (plasticity) upon unloading. TYPE=PERMANENT DEFORMATION must be used in conjunction with the DIRECTION parameter.
Rate-independent elastic models do not require the definition of unloading data. Nonelastic models and rate-dependent models require the specification of unloading behavior using the UNLOADING DATA option.
The following parameters are optional and can be used only with TYPE=ELASTIC
- RATE DEPENDENT
-
Include this parameter equal to define rate-dependent loading data. If this parameter is omitted, the data are assumed to be rate independent.
- RATE INTERPOLATION
-
Set RATE INTERPOLATION=LINEAR (default) to use linear intervals for the relative motion rate while interpolating rate-dependent loading data.
Set RATE INTERPOLATION=LOGARITHMIC to use logarithmic intervals for the equivalent relative motion rate while interpolating rate-dependent loading data.
This parameter is ignored if the RATE DEPENDENT parameter is omitted.
The following parameter is optional and can be used only with TYPE=DAMAGE
- DAMAGE ONSET
-
Set this parameter equal to the displacement/strain value at which the onset of damage occurs.
The following parameters are optional, mutually exclusive, and can be used only with TYPE=PERMANENT DEFORMATION
- SLOPE DROP
-
Set this parameter equal to the relative drop in slope on the loading curve that defines the onset of plastic deformation. The default value is 0.1.
- YIELD ONSET
-
Set this parameter equal to the displacement/strain value at which the onset of yield occurs.
Data lines to define uniaxial behavior that depends on the displacement/rotation in the direction of the specified component of relative motion (the RATE DEPENDENT and INDEPENDENT COMPONENTS parameters are omitted)
- First line
Force or moment. (Provide the absolute value if the DIRECTION parameter is defined.)
Constitutive relative displacement or rotation. (Provide the absolute value if the DIRECTION parameter is defined.)
Temperature.
First field variable.
Etc., up to five field variables.
- Subsequent lines (only needed if the DEPENDENCIES parameter has a value greater than five)
Sixth field variable.
Etc., up to eight field variables per line.
Repeat this set of data lines as often as necessary to define the loading curve data.
Data lines to define uniaxial behavior that depends on the relative positions or motions in several component directions (the RATE DEPENDENT parameter is omitted and the INDEPENDENT COMPONENTS parameter is included)
- First line
First independent component number (1–6).
Second independent component number (1–6).
Etc., up to entries. The independent components should not include the component for which the uniaxial loading behavior is being defined.
- Subsequent lines
Force or moment in the direction specified by the COMPONENT parameter on the CONNECTOR UNIAXIAL BEHAVIOR option. (Provide the absolute value if the DIRECTION parameter is defined.)
Constitutive relative displacement or rotation. (Provide the absolute value if the DIRECTION parameter is defined.)
Constitutive relative motion in the first independent component identified on the first data line.
Constitutive relative motion in the second independent component identified on the first data line.
Etc., up to entries as identified on the first data line.
Temperature.
First field variable.
Second field variable.
- If the number of data entries exceeds the limit of eight entries per line, continue the input on the next data line.
Do not repeat the first data line. Repeat the subsequent data lines as often as necessary to define the loading curve data.
Data lines to define rate-dependent uniaxial behavior in the direction of the specified component of relative motion (the RATE DEPENDENT parameter is included and the INDEPENDENT COMPONENTS parameter is omitted)
- First line
.
.
.
- Second line
Force or moment. (Provide the absolute value.)
Constitutive relative displacement or rotation. (Provide the absolute value.)
Relative velocity. (Provide the absolute value.)
Temperature.
First field variable.
Etc., up to four field variables.
- Subsequent lines (only needed if the DEPENDENCIES parameter has a value greater than four)
Fifth field variable.
Etc., up to eight field variables per line.
Do not repeat the first data line. Repeat the subsequent data lines as often as necessary to define the loading curve data.
Data lines to define rate-dependent uniaxial behavior that depends on the relative motions in several component directions (the RATE DEPENDENT and INDEPENDENT COMPONENTS parameters are included)
- First line
First independent component number (1–6).
Second independent component number (1–6).
Etc., up to entries. The independent components should not include the component for which the uniaxial loading behavior is being defined.
- Second line
.
.
.
- Subsequent lines
Force or moment in the direction specified by the COMPONENT parameter on the CONNECTOR UNIAXIAL BEHAVIOR option. (Provide the absolute value.)
Constitutive relative displacement or rotation. (Provide the absolute value.)
Relative velocity. (Provide the absolute value.)
Constitutive relative motion in the first independent component identified on the first data line.
Etc., up to entries as identified on the first data line.
Temperature.
First field variable.
Etc., up to eight entries per line.
- If the number of data entries exceeds the limit of eight entries per line, continue the input on the next data line.
Do not repeat the first and second data lines. Repeat the subsequent data lines as often as necessary to define the loading curve data.