Products
Abaqus/Standard
Abaqus/Explicit
Abaqus/CAE
Type
Model data
LevelModel
Abaqus/CAE
Property module
Optional parameters
-
DEPENDENCIES
-
This parameter applies only to Abaqus/Standard and Abaqus/Explicit analyses.
Set this parameter equal to the number of field variables, in addition to
temperature, on which the coefficients depend. If this parameter is omitted, it is
assumed that the thermal expansion is constant or depends only on temperature.
This parameter is not relevant if the
USER parameter is included or if in
an Abaqus/Standard analysis spatially varying thermal expansion is defined using a distribution (see
Distribution Definition).
-
FIELD
-
This parameter applies only to Abaqus/Standard analyses.
Set this parameter equal to the predefined field variable number for which field
expansion is being defined.
TYPE=TRANSVERSELY ISOTROPIC
cannot be used if this parameter is included.
-
LIQUID
- This parameter applies only to Abaqus/Standard analyses.
Include this parameter if the thermal expansion of the liquid is being
defined for the TNM model.
-
PORE FLUID
-
This parameter applies only to Abaqus/Standard analyses.
Include this parameter if the thermal expansion of the pore fluid in a porous medium
is being defined. The thermal expansion of a fluid must be isotropic, so
TYPE=ORTHO
and
TYPE=ANISO
cannot be used if this parameter is included.
-
PROPERTIES
-
This parameter applies only to Abaqus/Explicit analyses.
Set this parameter equal to the number of properties being entered.
The properties are available for use in user subroutine VUEXPAN. The default is
PROPERTIES=0.
-
TYPE
-
Set
TYPE=ISO
(default) to define isotropic expansion.
Set
TYPE=ORTHO
to define orthotropic expansion.
Set
TYPE=ANISO
to define fully anisotropic expansion.
Set
TYPE=SHORT FIBER
to define laminate material properties for each layer in each shell element. This
parameter setting is applicable only when using Abaqus/Standard in conjunction with the abaqus moldflow execution
procedure. Any data lines will be ignored. Material properties will be read from the
ASCII neutral file identified as
jobid.shf. See Translating Moldflow Data to Abaqus Input Files for more
information.
Set
TYPE=TRANSVERSELY ISOTROPIC
to define transversely isotropic expansion.
In an Abaqus/Standard analysis spatially varying isotropic, orthotropic, or anisotropic expansion can be
defined using a distribution. When using a distribution, the
TYPE parameter must be used to
indicate the level of anisotropy of thermal expansion. The level of anisotropy must be
consistent with that defined in the distribution. See Distribution Definition.
-
USER
-
Include this parameter to indicate that user subroutine UEXPAN in Abaqus/Standard and VUEXPAN in Abaqus/Explicit will be used to define increments of thermal strain. The
TYPE parameter should be used to
indicate the level of anisotropy of thermal expansion. The
PORE FLUID parameter can also be
used to indicate that the thermal expansion of the pore fluid is being defined.
TYPE=TRANSVERSELY ISOTROPIC
cannot be used if this parameter is included.
The DEPENDENCIES and
ZERO parameters are not relevant if
this parameter is used.
-
ZERO
-
If the thermal expansion is temperature- or field-variable-dependent, set this
parameter equal to the value of
. The default is
ZERO=0.
This parameter is not relevant if the
USER parameter or the
LIQUID parameter is included.
Data lines to define isotropic thermal expansion coefficients
(TYPE=ISO
with USER parameter
omitted)
- First line
-
in Abaqus/Standard or Abaqus/Explicit analysis. (Units of
−1.)
Temperature.
First field variable.
Etc., up to six field variables.
- Subsequent lines (only needed if the
DEPENDENCIES parameter has a value
greater than six)
-
Seventh field variable.
Etc., up to eight field variables per line.
Repeat this set of data lines as often as necessary to define the
thermal expansion coefficient as a function of temperature and other predefined field
variables.
Data lines to define orthotropic thermal expansion coefficients
(TYPE=ORTHO
with USER parameter
omitted)
- First line
-
. (Units of
−1.)
.
. (Not used for plane stress and shell cases.)
Temperature.
First field variable.
Etc., up to four field variables.
- Subsequent lines (only needed if the
DEPENDENCIES parameter has a value
greater than five)
-
Fifth field variable.
Etc., up to eight field variables per line.
Repeat this set of data lines as often as necessary to define the
thermal expansion coefficients as functions of temperature and other predefined field
variables.
Data lines to define anisotropic thermal expansion coefficients
(TYPE=ANISO
with USER parameter
omitted)
- First line
-
. (Units of
−1.)
.
. (Not used for plane stress and shell cases.)
.
. (Not used for plane stress and shell cases.)
. (Not used for plane stress and shell cases.)
Temperature.
First field variable.
- Subsequent lines (only needed if the
DEPENDENCIES parameter has a value
greater than one)
-
Second field variable.
Etc., up to eight field variables per line.
Repeat this set of data lines as often as necessary to define the
thermal expansion coefficients as functions of temperature and other predefined field
variables.
Data lines to define transversely isotropic thermal expansion coefficients
(TYPE=TRANSVERSELY ISOTROPIC)
- First line
-
. (Units of
−1.)
.
Temperature.
First field variable.
Etc., up to five field variables.
- Subsequent lines (only needed if the
DEPENDENCIES parameter has a value
greater than four)
-
Sixth field variable.
Etc., up to eight field variables per line.
Repeat this set of data lines as often as necessary to define the
thermal expansion coefficients as functions of temperature and other predefined field
variables.
Data line to define spatially varying thermal expansion in an Abaqus/Standard analysis using a distribution
- First (and only) line
-
Distribution name. The data defined in the distribution must be in units
of
−1 and must be consistent with the level of
anisotropy prescribed by the TYPE
parameter.
To define thermal expansion by a user subroutine
(USER parameter included)
No data lines are used with this option when the
USER parameter is specified. Instead, user
subroutine UEXPAN must be used to define the
thermal expansion. In Abaqus/Explicit data lines can be used to specify user properties that are passed in user subroutine
VUEXPAN to define the thermal
expansion.
Data lines to define isotropic field expansion coefficients
(TYPE=ISO
with USER parameter
omitted)
- First line
-
. (Units of
−1.)
Temperature.
First field variable.
Etc., up to six field variables.
- Subsequent lines (only needed if the
DEPENDENCIES parameter has a value
greater than six)
-
Seventh field variable.
Etc., up to eight field variables per line.
Repeat this set of data lines as often as necessary to define the
field expansion coefficient as a function of temperature and other predefined field
variables.
Data lines to define orthotropic field expansion coefficients
(TYPE=ORTHO
with USER parameter
omitted)
- First line
-
. (Units of
−1.)
.
.
Temperature.
First field variable.
Etc., up to four field variables.
- Subsequent lines (only needed if the
DEPENDENCIES parameter has a value
greater than four)
-
Fifth field variable.
Etc., up to eight field variables per line.
Repeat this set of data lines as often as necessary to define the
field expansion coefficients as functions of temperature and other predefined field
variables.
Data lines to define anisotropic field expansion coefficients
(TYPE=ANISO
with USER parameter
omitted)
- First line
-
. (Units of
−1.)
.
. (Not used for plane stress case.)
.
.
.
Temperature.
First field variable.
- Subsequent lines (only needed if the
DEPENDENCIES parameter has a value
greater than one)
-
Second field variable.
Etc., up to eight field variables per line.
Repeat this set of data lines as often as necessary to define the
field expansion coefficients as functions of temperature and other predefined field
variables.
To define field expansion by a user subroutine
(USER parameter included)
No data lines are used with this option when the
USER parameter is specified. Instead, user
subroutine UEXPAN must be used to define the
field expansion.