Products
Abaqus/Standard
Abaqus/CAE
Type
Model data
LevelModel
Abaqus/CAE
Property module
Optional parameters
-
DEPENDENCIES
-
Set this parameter equal to the number of field variables included in the
definition of diffusivity. If this parameter is omitted, the diffusivity
is assumed not to depend on any field variables but might still depend
on concentration and temperature. See Material Data Definition for more information.
-
LAW
-
Set
LAW=GENERAL
(default) to choose general mass diffusion behavior.
Set
LAW=FICK
to choose Fick's diffusion law.
LAW=FICK
and the KAPPA,
TYPE=TEMP
option are mutually exclusive.
-
SLURRY
-
This parameter applies only to Abaqus/Standard analyses.
Include this parameter to define the diffusivity of the particles in a
slurry in a geotechnical analysis that models slurry transport and
placement. The diffusivity of the particles must be isotropic.
This parameter cannot be used in conjunction with the
LAW and
TYPE parameters.
-
TYPE
-
Set
TYPE=ISO
(default) to define isotropic diffusivity. Set
TYPE=ORTHO
to define orthotropic diffusivity. Set
TYPE=ANISO
to define fully anisotropic diffusivity.
Data lines to define isotropic mass diffusivity
(TYPE=ISO)
- First line
-
-
Diffusivity, D. (Units of
L2T−1.)
-
Concentration, c.
-
Temperature,
.
-
First field variable.
-
Second field variable.
-
Etc., up to five field variables.
- Subsequent lines (only needed if the
DEPENDENCIES parameter has
a value greater than five)
-
-
Sixth field variable.
-
Etc., up to eight field variables per line.
Repeat this set of data lines as often as necessary to
define the diffusivity as a function of concentration, temperature, and
other predefined field variables.
Data lines to define mass orthotropic diffusivity
(TYPE=ORTHO)
- First line
-
-
. (Units of
L2T−1.)
-
.
-
.
-
Concentration, c.
-
Temperature,
.
-
First field variable.
-
Second field variable.
-
Third field variable
- Subsequent lines (only needed if the
DEPENDENCIES parameter has
a value greater than three)
-
-
Fourth field variable.
-
Etc., up to eight field variables per line.
Repeat this set of data lines as often as necessary to
define the diffusivity as a function of concentration, temperature, and
other predefined field variables.
Data lines to define anisotropic mass diffusivity
(TYPE=ANISO)
- First line
-
-
. (Units of
L2T−1.)
-
.
-
.
-
.
-
.
-
.
-
Concentration, c.
-
Temperature,
.
- Subsequent lines (only needed if the
DEPENDENCIES parameter is
used)
-
-
First field variable.
-
Etc., up to eight field variables per line.
Repeat this set of data lines as often as necessary to
define the diffusivity as a function of concentration, temperature, and
other predefined field variables.
Data lines to define the diffusivity of the particles in a
slurry
- First line
-
-
Diffusivity, D. (Units of
L2T−1.)
-
Temperature,
.
-
First field variable.
-
Second field variable.
-
Etc., up to six field variables.
- Subsequent lines (only needed if the
DEPENDENCIES parameter has
a value greater than six)
-
-
Seventh field variable.
-
Eighth field variable.
Repeat this set of data lines as often as necessary to
define the diffusivity as a function of temperature and other predefined
field variables.