Specifying design responses for a direct design sensitivity analysis
Optional parameters
- FREQUENCY
-
Set this parameter equal to the output frequency of the response sensitivities. The output will always be written to the output database at the last increment. If this parameter is omitted, output will be written at every increment of the analysis. Set FREQUENCY=0 to suppress output of the response sensitivities. This parameter also controls the frequency of the sensitivity calculations for the total DSA formulation.
- MODE LIST
-
Include this parameter to indicate that a list of eigenmodes for which sensitivities are desired will be listed on the data lines. This parameter is valid only in a FREQUENCY procedure.
Data lines to list desired eigenmodes if the MODE LIST parameter is included
- First line
-
Specify a list of desired eigenmodes.
Repeat this data line as often as necessary to list all desired eigenmodes.
-