ProductsAbaqus/StandardAbaqus/ExplicitAbaqus/CAE
TypeHistory data
LevelStep
Abaqus/CAEInteraction module
Required parameters
- NAME
-
Set this parameter equal to the label that will be used to identify the
co-simulation controls. All co-simulation control names in the same input file
must be unique.
Optional parameters
- FACTORIZATION FREQUENCY
-
This parameter is valid when used with the TIME INCREMENTATION=SUBCYCLE parameter.
Set FACTORIZATION FREQUENCY=EXPLICIT INCREMENT (default) to specify factoring of the interface matrix every
Abaqus/Explicit
increment.
Set FACTORIZATION FREQUENCY=STANDARD INCREMENT to specify factoring of the interface matrix once per
Abaqus/Standard
increment.
- TIME INCREMENTATION
-
Set TIME INCREMENTATION=SUBCYCLE (default) to allow
Abaqus
to take one or more increments to reach the next target time to exchange data
with the external program. This setting is valid only in an
Abaqus/Standard
or
Abaqus/Explicit
analysis.
Set TIME INCREMENTATION=LOCKSTEP to force
Abaqus
to use only one increment to reach the next target time.
There are no data lines associated with this option.