*BULK VISCOSITY

Modify bulk viscosity parameters.

This option is used to redefine bulk viscosity parameters in a model.

This page discusses:

See Also
In Other Guides
Explicit Dynamic Analysis

ProductsAbaqus/ExplicitAbaqus/CAE

TypeHistory data

LevelStep

Abaqus/CAEStep module

There are no parameters associated with this option.

 

Data line to define the bulk viscosity parameters

First (and only) line
  1. Linear bulk viscosity parameter, b1. If the BULK VISCOSITY option is omitted or is specified without the data line, the default value is 0.06. If the data line is given and the value of b1 is omitted, the default value is 0.0.

  2. Quadratic bulk viscosity parameter, b2. If the BULK VISCOSITY option is omitted or is specified without the data line, the default value is 1.2. If the data line is given and the value of b2 is omitted, the default value is 0.0.