From the menu in the Edit Material dialog box, select .
(For information on displaying the Edit Material dialog
box, see Creating or editing a material.)
-
Enter values for Secondary Surface Emissivity and
Main Surface Emissivity.
-
Enter the following data in the Data table:
- Effective View Factor
-
Effective view factor.
- Gap Clearance
-
Gap clearance.
Repeat this data line as often as necessary to define the dependence of the
view factor on gap clearance.
For detailed information on how to enter data, see Entering tabular data.
-
Click OK to close the Edit Material
dialog box. Alternatively, you can select another material behavior to define
from the menus in the Edit Material dialog box (see Browsing and modifying material behaviors, for more information).
|