- From the menu bar in the Edit Material dialog box, select .
(For information on displaying the Edit Material dialog box, see Creating or editing a material.) - Toggle on Use temperature-dependent data to define the bulk moduli as a function of temperature.
A column labeled Temp appears in the Data table. - Enter the following data in the Data table:
- Bulk mod of grains
Bulk modulus of solid grains. (Units of FL−2.)
- Bulk mod of fluids
Bulk modulus of permeating fluid. (Units of FL−2.)
- Temp
Temperature.
For detailed information on how to enter data, see Entering tabular data. - Click OK to close the Edit Material dialog box. Alternatively, you can select another material behavior to define from the menus in the Edit Material dialog box (see Browsing and modifying material behaviors, for more information).
|