- Create a material model as described in Defining a Drucker-Prager model.”
- From the menu in the Edit Material dialog box, select Triaxial Test Data.
A Suboption Editor appears. - Enter values for Material constant a, Material constant b, and Material constant pt if they are known and held fixed at the input value. Alternatively, you can leave one or more of the fields blank if you want Abaqus to calibrate the values from the triaxial test data.
- Enter the following data in the Data table:
- Confining Stress
Sign and magnitude of the confining stress, .
- Loading Dirn Stress
Sign and magnitude of the stress in the loading direction, .
For detailed information on how to enter data, see Entering tabular data. - Click OK to return to the Edit Material dialog box.
|