Abaqus/CAE
uses the following terms to describe the status of objects in particular
steps:
Created
The object was created and becomes active in this step. The point in the
step at which a prescribed condition becomes active depends on the amplitude
variation associated with that step. For more information, see
“Prescribed
conditions” in
Defining an Analysis.
Computed
The analysis products will compute the value of the object in this step.
Modified
The definition of the object has been modified in this step. The variation
of a prescribed condition over the course of the step depends on the amplitude
variation associated with that step.
Propagated
The object was created, modified, or computed in an earlier step of the
analysis and continues to be active in this step.
Deactivated
The object has been deactivated in this step or in a previous step. It will
remain deactivated in all subsequent steps until you reactivate it. You cannot
deactivate an object in the step in which it was created. The point in the step
at which a prescribed condition becomes inactive depends on the amplitude
variation associated with that step. For more information, see
“Prescribed
conditions” in
Defining an Analysis.
You cannot deactivate predefined fields; a deactivated status for a
predefined field means that the field has been reset to the value specified in
the initial step. The point in the step at which an object resumes its initial
value depends on the amplitude variation associated with that step. For more
information, see “Prescribed
conditions” in
Defining an Analysis.
N/A
The object does not have any effect on the calculations for this step.
The following terms apply only in linear perturbation steps:
Built into base
state
Any active object created in a preceding general analysis step will be part
of the base state and cannot be changed during the linear perturbation step.
Propagated from
base state
Objects created in a previous general step will be part of the base state
for this procedure but can be modified or deactivated by the user.
Deactivated from
base state
Objects created in a previous general step are deactivated in this linear
perturbation step. The deactivated state applies only to the linear
perturbation step and does not propagate to the remaining steps.
The following term applies only in modal dynamics steps:
Built into modes
Boundary conditions that are active in a preceding frequency analysis step
are used in the calculation of modes and will therefore be built into the modes
for mode-based linear perturbation procedures and subspace dynamic procedures.
During these mode-based and subspace dynamic procedures the boundary condition
cannot be changed.
Figure 1
shows the color codes assigned to various object statuses. The table cells in
step-dependent managers are colored accordingly to indicate the object status.