At high temperatures glass behaves like a liquid, while at low temperatures glass behaves
like a thermoelastic solid. In both temperature ranges the physical properties of glass
depend only on the instantaneous value of the temperature. However, at temperatures in the
vicinity of the glass transition temperature the behavior of glass is different. In this
temperature range, the molecular structure of glass changes gradually with temperature and a
noticeable delay is observed before the equilibrium state is reached. In this case the
physical properties depend on both the temperature and the thermal history.
Tool-Narayanaswamy-Moynihan Model
In Abaqus/Standard the Tool-Narayanaswamy-Moynihan (TNM) model can be used
to predict structural relaxation in glass. It uses the fictive temperature, , originally proposed by Tool to describe the structure of the material.
In the TNM model the thermal strains are obtained from the
following relation:
where
is the thermal expansion coefficient for the glassy state;
is the thermal expansion coefficient for the liquid state;
is the current temperature;
is the initial temperature;
is the initial fictive temperature;
are the current values of the predefined field variables;
are the initial values of the predefined field variables; and
is the reference temperature for the thermal expansion coefficients.
For a special case when the thermal expansion coefficients are not temperature- or field
variable-dependent, it can be shown that the thermal strain increment can be expressed as
In the TNM model we must specify the coefficients of
thermal expansion for both glassy and liquid states.
Input File Usage
Use the following option to define the thermal expansion coefficient for the glassy
state:
If the coefficients of thermal expansion are not functions of temperature or field
variables, the value of the reference temperature, , is not required. If or is a function of temperature or field variables, you can define .
Input File Usage
Use the following option to define the reference temperature value:
The fictive temperature at time is computed using the algorithm proposed by Markovsky and Soules:
and
Elements
The structural relaxation model can be used with any stress/displacement element in Abaqus/Standard.
Procedures
The model can be used with all stress/displacement procedure types. However, the time
effects are taken into account only in quasi-static (see Quasi-Static Analysis), coupled temperature-displacement (see Fully Coupled Thermal-Stress Analysis), and direct-integration implicit dynamic (see Implicit Dynamic Analysis Using Direct Integration) analyses. In other stress/displacement procedure types the
evolution of the fictive temperature is suppressed, so its value remains unchanged.
Markovsky, A., and T. F. Soules, “An
Efficient and Stable Algorithm for Calculating Fictive
Temperatures,” Journal of the American
Ceramic
Society, vol. 67, no. 4, pp. 56–57, 1984.
Narayanaswamy, O.S., “A
Model of Structural Relaxation in
Glass,” Journal of the American Ceramic
Society, vol. 54, no. 10, pp. 491–498, 1971.
Tool, A.Q., “Relation
Between Inelastic Deformation and Thermal Expansion of Glass in Its Annealing
Range,” Journal of the American Ceramic
Society, vol. 29, no. 9, pp. 240–253, 1946.