Products
Abaqus/Standard
Abaqus/Explicit
Type
Model data
LevelModel
Required parameters
-
TYPE
-
Set
TYPE=EXPONENTIAL
to use exponential viscous softening.
Set
TYPE=TABULAR
to use tabular viscous softening.
Data line for
TYPE=EXPONENTIAL
- First (and only) line
-
Maximum level of softening,
.
Characteristic equivalent creep strain,
.
Data lines for
TYPE=TABULAR
- First line
-
Viscous softening scaling
factor.
Equivalent creep strain.
Repeat this data line as often as necessary to define the
viscous softening scaling factor as a function of equivalent creep
strain. The scaling factor on the first line must be 1.0, and the
equivalent creep strain on the first line must be
0.0.