Products
Abaqus/Explicit
Abaqus/CAE
Type
History data
LevelStep
Abaqus/CAE
Step module
Required parameters
-
EXPLICIT
-
Include this parameter to specify explicit time integration.
Optional, mutually exclusive parameters
-
DIRECT USER CONTROL
-
Include this parameter to specify that this step should use a fixed time
increment that is specified by the user.
-
ELEMENT BY ELEMENT
-
Include this parameter to indicate that variable, automatic time
incrementation using the element-by-element stable time increment
estimates should be used. This method will generally require more
increments and more computational time than the global time
estimator.
-
FIXED TIME INCREMENTATION
-
Include this parameter to specify that this step should use a fixed time
increment that will be determined by Abaqus/Explicit at the beginning of the step using the element-by-element time
estimator.
Optional parameters
-
IMPROVED DT METHOD
-
Set
IMPROVED DT METHOD=YES
(default) to use the improved method to estimate the
element stable time increment due to the mechanical response for
three-dimensional continuum elements and elements with plane stress
formulations (shell, membrane, and two-dimensional plane stress
elements).
Set
IMPROVED DT METHOD=NO
to use the conservative method to estimate the element stable time
increment due to the mechanical response for three-dimensional continuum
elements and elements with plane stress formulations.
-
RATE DEPENDENCE
-
Set
RATE DEPENDENCE=ON
(default) to consider material strain rate–dependence.
Set
RATE DEPENDENCE=OFF
to ignore material strain rate–dependence. Definitions of
thermorheologically simple temperature dependence are also ignored.
-
SCALE FACTOR
-
Set this parameter equal to the factor that is used to scale the time
increment computed by Abaqus/Explicit. The default scaling factor is 1.0. This parameter can be used to
scale the default global time estimate, and it can be used in
conjunction with the
ELEMENT BY ELEMENT and
FIXED TIME INCREMENTATION
parameters. It cannot be used in conjunction with the
DIRECT USER CONTROL
parameter.
Data line for automatic time incrementation (global or
ELEMENT BY ELEMENT
estimation)
- First (and only) line
-
Enter a blank field.
T, time period of the
step.
Enter a blank field.
, maximum time increment allowed. If this value
is not specified, no upper limit is imposed.
Data line for fixed time incrementation using
DIRECT USER CONTROL
- First (and only) line
-
, time increment to be used throughout the
step.
T, time period of the
step.
Data line for fixed time incrementation using
FIXED TIME INCREMENTATION
- First (and only) line
-
Enter a blank field.
T, time period of the
step.