From the main menu bar, select .
-
In the Create Interaction Property dialog box that
appears, do the following:
-
Click Continue to close the Create Interaction
Property dialog box.
-
From the menu bar in the contact property editor, select .
The Edit Contact Property dialog box appears.
-
In the editor that appears, click the arrow to the right of the
Definition field, and select an option for defining
electrical conductance:
- Select Tabular to enter data relating electrical
conductance to the separation between the contact surfaces.
- Select User-defined to define the conductance in
user subroutine GAPELECTR. If you
select this option, skip to Step 12.
-
Indicate whether you want to define the electrical conductivity in the
Solid material or Liquid
electrolyte.
-
Indicate whether you want to define electrical conductance as a function of the
clearance between the surfaces, the contact pressure between the surfaces, or
both.
-
If you want to define electrical conductance as a function of clearance for the
electrical conductivity in the solid material, display the Clearance
Dependency tabbed page, and do the following:
-
Toggle on Use temperature-dependent data if the
data are dependent on temperature.
-
Click the arrows to the right of the Number of field
variables field to specify the number of field variables
on which the data depend.
-
In the data table, define electrical conductance as a function of gap
clearance.
The tabular data must start at zero clearance (closed gap) and define
electrical conductance as clearance increases. You must provide at least
two pairs of points. The value of electrical conductance drops to zero
immediately after the last data point, so there is no conductance when
the clearance is greater than the value corresponding to the last data
point. If conductance is not also defined as a function of contact
pressure, it will remain constant at the zero clearance value for all
pressures.
-
If you want to define electrical conductance as a function of contact pressure
for the electrical conductivity in solid material, display the
Pressure Dependency tabbed page, and do the
following:
-
Toggle on Use temperature-dependent data if the
data are dependent on temperature.
-
Click the arrows to the right of the Number of field
variables field to specify the number of field variables
on which the data depend.
-
In the data table, define electrical conductance as a function of
contact pressure at the interface.
The tabular data must start at zero contact pressure (or, in the case
of contact that can support a tensile force, the data point with the
most negative pressure) and define electrical conductance as pressure
increases. The value of electrical conductance remains constant for
contact pressures outside of the interval defined by the data points. If
conductance is not also defined as a function of clearance, it is zero
for all positive values of clearance and discontinuous at zero
clearance
-
If you want to define electrical conductance as a function of clearance for the
electrical conductivity in liquid electrolyte, display the Clearance
Dependency tabbed page, and do the following:
-
Toggle on Use temperature-dependent data if the
data are dependent on temperature.
-
Toggle on Use ion-concentration-dependent data if
the data are dependent on ion-concentration.
-
Click the arrows to the right of the Number of field
variables field to specify the number of field variables
on which the data depend.
-
In the data table, define electrical conductance as a function of gap
clearance.
The tabular data must start at zero clearance (closed gap) and define
electrical conductance as clearance increases. You must provide at least
two pairs of points. The value of electrical conductance drops to zero
immediately after the last data point, so there is no conductance when
the clearance is greater than the value corresponding to the last data
point. If conductance is not also defined as a function of contact
pressure, it will remain constant at the zero clearance value for all
pressures.
-
If you want to define electrical conductance as a function of contact pressure
for the electrical conductivity in liquid electrolyte, display the
Pressure Dependency tabbed page, and do the
following:
-
Toggle on Use temperature-dependent data if the
data are dependent on temperature.
-
Toggle on Use ion-concentration-dependent data if
the data are dependent on ion concentration.
-
Click the arrows to the right of the Number of field
variables field to specify the number of field variables
on which the data depend.
-
In the data table, define electrical conductance as a function of
contact pressure at the interface.
The tabular data must start at zero contact pressure (or, in the case
of contact that can support a tensile force, the data point with the
most negative pressure) and define electrical conductance as pressure
increases. The value of electrical conductance remains constant for
contact pressures outside of the interval defined by the data points. If
conductance is not also defined as a function of clearance, it is zero
for all positive values of clearance and discontinuous at zero
clearance
-
Click OK to create the contact property and to exit the
Edit Contact Property dialog box.
Alternatively, you can select another contact property option to define from