Individual nodes and elements are changed during the optimization. Thus, the commands used in Abaqus to define nodes and elements of transformations are invalid. The appearance of these options in the finite element input file leads to a termination of the optimization. Therefore, these definitions should be executed in a preprocessor such that an explicit definition of the nodes and elements is created. When input files already exist, then a data check should be carried out with Abaqus. In this data check, the nodes and elements are generated and written in the output file (*.dat). The node and element definitions can then be copied from the output file and inserted into a new input file.
Parametric inputs in the Abaqus
input file will be recognized by Tosca Structure.
A new input file is created with these parameters replaced. The original input file can be found in the starting directory with the ending Tosca Structure Support of Abaqus Encrypted FilesTosca Structure needs to read all model data, nodes, elements, loads and boundaries that are referenced in the optimization problem (as design area, DRESPs, etc.). Encrypted cards are generally allowed outside the design domain. Encrypted material cards are allowed if:
| |||||||