Products
Abaqus/Standard
Type
Model data
LevelThis option is not supported in a model defined in terms of an assembly of part instances.
Optional parameters
-
STEP
-
Set this parameter equal to the step number on the restart file at which
the results must be obtained. If this parameter is omitted, the results
will be obtained at the last available step found on the restart
file.
-
INC
-
Set this parameter equal to the increment number on the restart file at
which the results must be obtained. If this parameter is omitted, the
results will be obtained at the end of the step specified by the
STEP parameter.
-
ITERATION
-
This parameter is relevant only if the solution is transferred from a
previous direct cyclic analysis.
Set this parameter equal to the iteration number on the restart file at
which the results must be obtained. Since restart information can be
written only at the end of an iteration in a direct cyclic analysis, the
INC parameter is
irrelevant and is ignored if the
ITERATION parameter is
specified.
If this parameter is omitted, the results will be obtained at the end of
the step specified by the
STEP parameter.
-
LIBRARY
-
Set this parameter equal to a value that specifies the previous analysis
from which to transfer results to a three-dimensional model. You can
specify the name of the previous analysis or the name including the full
path.
If you do not specify the path, all input files and results files from
the previous analyses must reside in the current (working) directory.
-
UNBALANCED STRESS
-
Set
UNBALANCED STRESS=STEP
(default) if the stress unbalance is to be resolved in the first
increment.
Set
UNBALANCED STRESS=RAMP
if the stress unbalance is to be resolved linearly over the step.
There are no data lines associated with this option.